P/N 1072772-EN • REV C • ISS 01FEB19 

 

3 / 4 

 

3.  Use the screws to screw the wall-mount plate on the 

industrial gigabit Ethernet switch. 

 

4.  Use the hook holes at the corners of the wall-mount plate 

to hang the industrial gigabit Ethernet switch on the wall.

 

5.  To remove the wall-mount plate, reverse the steps above. 

Starting web management 

The section describes how to start up the web management 
function for the industrial managed switch. Note that the 
industrial managed switch is configured through an Ethernet 
connection. Ensure that the manager computer is set to the 
same IP subnet address. 

For example, if the default IP address of the industrial 
managed switch is 192.168.0.100, then the manager computer 
should be set to 192.168.0.x (where x is a number between 1 
and 254, except 100), and the default subnet mask is 
255.255.255.0. 

Figure 3: IP management diagram 

 

Logging in to the industrial managed switch  

1.  Use the Internet Explorer 8.0 or later web browser and 

type the IP address http://192.168.0.100

 

(the factory-

default IP address) to access the web interface.  

2.  When the following dialog box appears, enter the default 

user name “admin” and password “admin” (or the 
password you have changed before) as shown in Figure 4 
below. 

 

Default IP Address: 

192.168.0.100 

Default User Name: 

admin 

Default Password: 

admin 

Figure 4: Login screen 

 

3.  After typing the password, the main screen appears as 

shown in Figure 5 below.  

Figure 5: Main web interface screen 

 

4.  The switch menu on the left side of the web page permits 

access to all the functions and status provided by the 
industrial managed switch.  

 

Refer to the User Manual for further information about using 
the web management interface. 

Note

: For security purposes, change and memorize the new 

password after this first setup. 

Содержание NS3550-8T-2S

Страница 1: ...acking materials for repacking the product in case there is a need to return it to us for repair Requirements The industrial managed switch provides a remote login interface for management purposes The following equipment is necessary for further management Workstations running Windows XP 2003 Vista 7 8 2008 10 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Wo...

Страница 2: ...vice while the AC power cord is plugged in This is not a hot swappable switch Hot swapping this device will result in damage DIN rail mounting installation To replace the wall mount application with DIN rail application on industrial gigabit Ethernet switch refer to the following figures to screw the DIN rail on the industrial gigabit Ethernet switch To hang the industrial gigabit Ethernet switch ...

Страница 3: ...100 and the default subnet mask is 255 255 255 0 Figure 3 IP management diagram Logging in to the industrial managed switch 1 Use the Internet Explorer 8 0 or later web browser and type the IP address http 192 168 0 100 the factory default IP address to access the web interface 2 When the following dialog box appears enter the default user name admin and password admin or the password you have cha...

Страница 4: ... Click the Save Configuration button Resetting the switch to default To reset the IP address to the default IP address 192 168 0 100 and the user password to factory default mode default password is admin press the hardware reset button on the front panel for about 10 seconds After the device is rebooted log in to the management web interface within the same subnet of 192 168 0 xx and default pass...

Отзывы: