manualshive.com logo in svg
background image

 

2  

Learn Mode Freeze Sensor Installation Instructions 

Figure 1: Base release tab location 

3.  Place transmitter in sensor cover to protect circuit board 

against static damage. 

4.  Secure the sensor base to mounting surface by using #6 

pan head screws or #18 x 1/2” wire nails (brads). If 
mounting on plaster, use the appropriate fasteners. Use 

the slotted mounting hole for alignment. See Figure 2.  

Figure 2: Mounting hole locations 

5.  Replace the sensor circuit board on the base. Place the 

reed switch end in first, then snap the board in place at the 

base release tab.  

6.  Do not replace the sensor cover at this time. 

Programming 

General guidelines for programming this divce are: 

 

1.  Set the CPU into Program Mode. 

2.  Trip the 

device’s tamper switch. See Figure 1. 

3.  Replace the sensor cover. 

Note

: Refer to the appropriate CPU installation manual for 

specific instructions for programming device into the CPU. 

Testing 

General guidelines for performing a Dealer Signal Strength 

Test are: 

1.  Using the appropriate touchpad for the CPU, enter the 

applicable Dealer Sensor Test code. 

2.  Cool thermal couple with a piece of ice in a plastic bag. 

When the thermal couple reaches ~45°F, the transmitter 

sends an RF signal to the CPU. 

3.  Note the number of beeps from the CPU. These beeps 

indicate 

the device’s signal strength. 

4.  The device resets when the surrounding temperature 

reaches 55°F-60°F 

Regulatory information 

Manufacturer 

UTC Fire & Security Americas Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, MN 55112-6943, 
USA 

FCC compliance 

This device complies with part 15 of the FCC 
Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any 
interference received, including interference that 
may cause undesired operation.  

Changes or modifications not expressly approved 
by Interlogix can void the user’s authority to 
operate the equipment. 

FCC ID: B4Z-561M-FREEZE 

IC compliance 

IC: 1175C-561FREEZE  

This Class B digital apparatus complies with 
Canadian ICES-003.  

Cet appareil numérique de la classe B est 
conforme à la norme NMB-003 du Canada.  

Le fonctionnement est soumis aux deux 
conditions suivantes : (1) cet appareil peut ne pas 
provoquer d’interférences et (2) cet appareil doit 
accepter toutes interférences, y compris les 
interférences pouvant provoquer un 
fonctionnement non désiré de l’appareil.  

Contact information 

For general information, see 

www.interlogix.com

. For 

customer/technical support, see 

www.interlogix.com/customer-

support

  or call +1 855 286 8889. 

© 2014 United Technologies Corporation. Interlogix is part of 

UTC Building and Industrial Systems, a unit of United 

Technologies Corporation. All rights reserved. 

 