• The partition touchpad you are using must arm/disarm that partition. You can
also arm/disarm additional partitions.
Keychain touchpad arming/disarming
To arm multiple partitions at the same time from a keychain touchpad, press the
Lock button. To disarm multiple partitions at the same time from a keychain
touchpad, press the Unlock button.
Use the following guidelines to arm/disarm multiple partitions from keychain
touchpads:
• A partition cannot be armed or disarmed if it is being controlled by another
source at the same time. For example, if you press the Lock button
attempting to arm Partition 1 and 2, a Partition 2 touchpad in use at the same
time prevents arming.
• When arming multiple partitions, any conditions that prevent arming (open,
trouble, active alarm, etc.) are identified on system touchpad displays in the
affected partition, while other touchpad displays show
PROTEST
. The normal
protest/auto force arm sequence follows, or you can press * on a system
touchpad to cancel the arming request. Pressing the Lock button again during
the protest condition bypasses any open sensors in the associated partitions
and arms those partitions.
• When disarming multiple partitions and alarms are active in one or more of
the associate partitions:
• Protest beeps sound for 5 minutes in all partitions being disarmed.
• Partitions in alarm where sirens have timed out sound protest beeps for 5
minutes.
• Partitions in alarm with active sirens continue sounding the alarm.
WARNING:
Anytime fire alarms are active, premises may not be safe to enter.
Proceed as follows: 1. Leave and call for help from a safe location and wait for
authorities to arrive. 2. When it is determined safe to enter the premises, go to a
system touchpad and check the system status to determine the alarm source.
Disarm and alarm memory is displayed for all associated partitions. 3. Press the
Unlock button a second time (within the 5 minute protest period) to disarm all
associated partitions and cancel all alarms, then go to a system touchpad and
check alarm memory to determine the alarm source.
Macro keys
Your system may include touchpads with macro keys that allow one-touch
operation. These are four keys located at the bottom of the touchpad. From the
factory, these keys are labeled and work as follows: