![Interlogix ATS7200E Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/interlogix/ats7200e/ats7200e_installation-sheet_2076770004.webp)
4 / 32
P/N 466-
2983 (ML) • REV A • ISS 06AUG18
Check mode
To playback the recorded messages:
1. Press the push button (Figure 6, item 4) for less than one
second.
Note:
If it is pressed for more than 1 second, you go back
into programming mode.
2. Listen to the messages that you have been recorded.
Note:
At the end of either Record mode or Check mode,
there will be 7 beeps to indicate that the module is now
available for event reporting.
Programming the Advisor Advanced
Refer to the Advisor Advanced programming manual.
Programming the Advisor Master
After recording the messages, program the Advisor Master by
selecting the Voice protocol for 1 to 4 Central Stations (CS).
Program the voice protocol in Communications Options menu
19/9 for CS 1 to 4 with format No. 14 without Acknowledge:
Voice Reporting – No Acknowledge
Format No: 14
Set Suppress FTC for voice reporting option to YES.
YES–Suppress FTC for voice reporting
*-Change 0-Skip
Map the recording voice message to one of the reporting
codes via menu 19/52. Refer to Table 3 below.
Burglar Alarm – Voice Message 0
Msg No:
Voice message programming table
Voice messages can be programmed to report on the
occurrence of specific reporting codes. More than 1 reporting
code may have the same voice message programmed.
Reporting codes 1 to 11 are general alarms, while reporting
codes 12 to 21 are zone specific, that is, you can program the
reporting codes to specific zones. The range is from 1 to 14.
Table 3: Reporting codes
#
Reporting code
1st ATS7200E
installed
Message no.
2nd ATS7200E
installed
Message no.
1.
Burglar Alarm
1
–6
1
–14
2.
Tamper Alarm
1
–6
1
–14
3.
Hold-up Alarm
1
–6
1
–14
4.
Panic Alarm
1
–6
1
–14
5.
Fire Alarm
1
–6
1
–14
6.
Medical Alarm
1
–6
1
–14
7.
Technical Alarm
1
–6
1
–14
8.
Mains Fail
1
–6
1
–14
9.
DGP Offline
1
–6
1
–14
10.
Area Disarmed
1
–6
1
–14
#
Reporting code
1st ATS7200E
installed
Message no.
2nd ATS7200E
installed
Message no.
11.
Area Armed
1
–6
1
–14
12.
130 BA Burglary
1
–6
1
–14
13.
131 BA Perimeter
1
–6
1
–14
14.
132 BA Interior
1
–6
1
–14
15.
133 BA 24 Hour
1
–6
1
–14
16.
134 BA Entry/Exit
1
–6
1
–14
17.
135 BA Day/Night
1
–6
1
–14
18.
136 BA Outdoor
1
–6
1
–14
19.
137 BA Tamper
1
–6
1
–14
20.
138 BA Near Alarm
1
–6
1
–14
21.
140 UA General Alarm
1
–6
1
–14
Default message number 0 = No message.
Reporting code 12 (130, BA Burglary) and reporting code 1 (Burglar
Alarm) are the same events. If reporting code 12 (130, Burglary) is
programmed with an alarm message, then this will override reporting
code 1 (Burglar Alarm).
Specifications
Power supply
12 V
via ribbon cable
from control panel
Supply current
50 mA
Recording capacity
8 messages
(total recording time 40 s)
Recording bandwidth
3 kHZ
Dimensions
80 x 50 x 20 mm
Weight
123 g
Temperature
+10 to 50°C
Non-volatile memory
Yes
Automatic gain control during recording
Yes
Acknowledge by DTMF code
“0”
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY
“AUTHORIZED
DEALER
” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Содержание ATS7200E
Страница 32: ...32 32 P N 466 2983 ML REV A ISS 06AUG18 ...