8
ATS1745 Advisor Master IP Bus adaptor installation & Setup Guide
Preliminary, not for sales
Programming assigned network parameters
First program the SLM with its assigned network parameters and then program
each ELM with the assigned network parameters for both the SLM and the ELM.
To program the SLM’s assigned network parameters:
1. Select the ATS1745 module with SW1 in the ON position (Figure 4, item 7,
on page 2).
2. Connect power and Ethernet cables to the module (Figure 4 on page 2).
3. Start Internet Explorer on a computer connected to the network, type
“192.168.20.100” in the address bar, and then press Enter. You should see a
screen similar to Figure 7 on page 11.
4. Log in to the SLM’s Web interface. See “Logging in” on page 11.
5. Type the assigned network parameters in the SLM’s Device Configuration
window under the Host heading, and then click Save. After a few seconds,
the Web browser will redirect to the login window at the new IP address.
If the module is not yet installed, we recommend that you attach a tag to the module
to identify its role (SLM) and its IP address until the module is installed.
To program each ELM’s assigned network parameters:
1. Select an ATS1745 module with SW1 in the OFF position (Figure 4, item 7,
on page 2).
2. Connect power and Ethernet cables to the module (Figure 4 on page 2).
3. Start Internet Explorer on a computer connected to the network, type
“192.168.20.105” in the address bar, and then press Enter. You should see a
screen similar to Figure 7 on page 11.
4. Log in to the ELM’s Web interface. See “Logging in” on page 11.
5. Type the SLM’s assigned IP address in the ELM’s Device Configuration
window under the Remote heading, and then click Save IP.
6. Type the ELM’s assigned network parameters in the ELM’s Device
Configuration window under the Host heading, and then click Save. After a
few seconds, the Web browser will redirect to the login window at the new IP
address.
7. Repeat steps 1 to 6 for each subsequent ELM. If necessary, disconnect
Ethernet and power cabling from the previously programmed ELM to use on
the subsequent ELM.
If the module is not yet installed, we recommend that you attach a tag to the module
to identify its role (ELM 1, ELM 2, and so on) and its IP address until the module is
installed.