Note

: Be certain to carefully locate field of view for required 

detection. As with all PIR units, there is no detection between 

fields of view. Installation must be tested one or more times 

yearly. 

page 2). The unit is factory set in the increased sensitivity 

mode. 

Standard Sensitivity

 - 

All 40-foot-wide

(12.2m) applications (left, right, or full). Use
with patterns E, G and H only. See Figure 7.

Increased Sensitivity - 

80-foot-wide

(24.4m) angle areas, 40-foot (12.2m) curtain
only or  long-range applications. Use with
patterns A through L. See Figure 7.

High Sensitivity -

Use only in hazard-free, high-

security applications. Use with patterns A through
L. See Figure 7.

 

Setting the LED 

Use 

Jumper D 

to enable/disable the LED. The LED is factory 

set in the enabled mode. See Figure 5 on page 2. 

e

l

b

a

s

i

D

 

D

E

L

e

l

b

a

n

E

 

D

E

L

 

Optional swivel bracket 

Note

: The unit ships with the 200-foot (61.0m) plastic mask 

(marked "6") insert in place. The 40-foot (12.2m) center curtain 

is always enabled to ensure undercrawl detection. 

For special applications, an optional swivel bracket is available 

see Figure 6 below. 

Testing zone locations 

Figure 6: Optional swivel bracket 

The test feature allows you to identify each zone of coverage 

and avoid “splitting” a zone of coverage between two areas 

with dissimilar infrared energy levels, such as a metal door and 

a freezer. 

Jumper B 

is factory set with the test mode disabled 

(see Figure 5 on page 2). To test the zone locations: 

 

1.   Insert Jumper B so that both pins are covered.

2. Without stopping, walk across the coverage

pattern and watch the unit. Each time you
enter a zone, the green LED illuminates.
When the green LED goes out,  you are in the
center of a zone or between two zones.

3.    After identifying each zone location, return

the unit to normal mode by inserting Jumper
B on only one pin so that the two pins are not
connected.

Test - On

Test - Off

 

 

AP633A Passive Infrared Detector Installation Instructions  

Содержание AP633A

Страница 1: ...ectly onto the unit Heat sources or mobiles in the field of view Strong air drafts blowing onto the unit Animals in the field of view Insects in the housing or on the face of the unit Rapid temperature changes in the field of view Very strong sources of RF energy and induction of electrical noise Installing the unit 1 Loosen the screw at the bottom of the unit then remove the front housing Figure ...

Страница 2: ...minals 33ohm 1 2 3 4 5 6 7 8 NEG 12V Alarm Tamper Spare Terminal AP633A 1 Negative 2 Positive 3 Closed Loop Contact 4 Common 5 Open Loop Contact 6 Tamper Closed Loop 7 Tamper Closed Loop 8 Spare not used Aiming the unit To ensure proper coverage make subtle pattern adjustments using the three adjustment screws located inside the unit see Figure 5 below The top screw adjusts the unit s coverage pat...

Страница 3: ...0 foot 61 0m plastic mask marked 6 insert in place The 40 foot 12 2m center curtain is always enabled to ensure undercrawl detection For special applications an optional swivel bracket is available see Figure 6 below Testing zone locations Figure 6 Optional swivel bracket The test feature allows you to identify each zone of coverage and avoid splitting a zone of coverage between two areas with dis...

Страница 4: ...on 25mA average normal operation LED enabled 40mA max Contact rating Alarm 100mA 28 VDC with 33 ohm resistor in series Tamper 100mA 28 VDC Coverage pattern 12 selectable patterns using snap on blockers Mounting height 6 to 10 1 8m to 3 0m Operating temperature 0 F to 131 F 18 C to 55 C Dimensions 6 3 x 4 1 x 3 0 16 0cm x 10 4cm x 7 6cm Regulatory information Listings UL 639 Ordering information Pa...

Отзывы: