Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
71
• Part set 1-unset / Part set 2-unset: One badge partially sets or unsets areas.
Note:
If the user privileges
allow him to control doors, and “2.2.1.n.3.5.1 1 x door
” on page 70 is set to Yes, the door access is also granted upon one-time
badge unset. If there are messages that require acknowledge, the access is
granted only after the acknowledgement.
2.2.1.n.3.5.4 3 x badge set
4 3xbadge set
>Off<
Three-time badge to set defines if the selected keypad allows you to set areas
with triple badge. The following values are available:
• Off: Triple badge does not cause any action.
• Set: Triple badge sets areas.
• Partset1 / Partset 2: Triple badge partially sets areas.
Notes
• This functionality works only if areas can be set with a card. See
“2.2.1.n.3.5.2 Card and PIN mode” on page 70 for available modes.
• This functionality is available only if the “2.2.1.n.3.5.3 1 x set/unset” option
described on page 70 is not configured as Set-Unset.
2.2.1.n.3.6 EE PIN lock
6 EE PIN lock
>No<
If the EE PIN lock option is set to Yes, it is not possible to use a PIN during the
entry time.
2.2.1.n.3.7 Isolate keypad
7 Isolate Rkp
>No<
Use the Isolate keypad option to isolate the tamper fault events on the selected
keypad. The keypad, however, remains functional.
2.2.1.n.3.8 Buzzer silent
8 Buzzer silent
>Never<
It is possible to disable the keypad buzzer for particular events. The following
options are available:
• Never: Buzzer operates normally. It is impossible to mute the buzzer using
X + Left volume control.
• During PS exit: Buzzer does not sound when part setting. The manual volume
control is available without limitations.
• Always: Buzzer is disabled. The manual volume control is available without
limitations.