2 / 8
P/N 1073507A
• REV 00.00 • ISS 4JUL18
Mounting
Figure 1: Mounting instructions
If the biometric reader is installed and used outdoor, the reader
MUST be fitted with cover available in our accessories in order
to protect the sensor from direct rainfall. The operating
temperature of the product is between -15 to + 50ºC. If the
reader is installed in an environment where the temperature
can drop below -10ºC or/and if the sensor could only be
exposed to direct sunlight, it is strongly recommended to install
the reader inside a third party sealed wall mount box (fitted
with additional heater if very low temperature) to keep a
constant sensor level performance. We cannot guarantee the
functionality of the product if measures and advice before are
not followed.
It is also strongly recommended to use double technology
biometric readers when use outdoor to offer first higher
security but also the possibility to use different readers
depending on users.
Wiring
Figure 2: Wiring
Wiring description
Dipswitch
1. not used
2. not used
3. not used
4.
Enable HID
(ON_OFF)
5.
Enable EM
or
CASI
(ON_OFF)
6. Select
EM
or
CASI
(ON-EM; OFF-Casi Rusco)
HID only HID and EM HID and Casi Casi only EM only
Connecting Biometric readers to controllers
Figure 3: Wiring instructions
•
Connect the lines D0, D1, LR-, LG-, GND and +12V to the
TruPortal controller.
•
Connect the RS485 Line (A, B) to the converter. Connect
the converter in the PC.
•
Fingerprint enrollment is done from the ACL800
BioManager software. Connection between the biometric
readers and the PC must be established.
•
The biometric readers communicate with each other with a
RS485 and with the ACL800 BioManager software through a
converter.
•
The RS485 Line should be configured in the form of a
daisy chain, NOT in a form of a star. Keep the stubs from the
RS485 backbone as short as possible (not more than 5
meters)
•
Only one converter per installation is needed, not per
reader.
12 VDC
Red
+12 VDC
GND
Black
Ground
A
Pink
A (RS485)
B
Violet
B (RS485)
Tamp
Blue
Tamper
Tamp
Green
Tamper
LG-
Yellow
LED green -
LR-
Orange
LED red -
D1
White
Data 1
D0
Green
Data 0