![background image](http://html.mh-extra.com/html/interlogix/60-677/60-677_installation-instructions_2076762005.webp)
Interrogator 200 Audio Verification Module (AVM) Installation Instructions
5
5. Walk through the AVM area of coverage while speaking at
a normal conversation level.
6. Have the operator speak to you.
7. When testing is complete, the operator will end the
session.
Sound volume
The AVM microphone volume is automatically controlled and is
not adjustable. The speaker volume is preset to full volume.
If it doesn’t work
AVM Communication failure usually occurs because of panel
programming errors. Check the programming selections you
made at the panel.
Specifications
Compatibility
UltraGard and Custom Versions
Power requirements
12 VDC, 10 mA (maximum)
Dimensions
6.9" L x 4.9" H x 2.5" D
Color Belgian
gray
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
FCC compliance
This device complies with part 15 of the FCC
rules. Operation is subject to the following two
conditions:
1)This device may not cause harmful
interference.
2)This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the users’ authority to
operate the equipment