background image

and skilled refrigeration service engineer and insist upon genuine Interlevin parts. If the 
appliance is under guarantee, please call the company from whom you purchased the 
appliance. Always have the serial number to hand. The serial number is located on the 

4

.

0

  

IN THE EVENT OF A MALFUNCTION

inside wall of the refrigerated compartment. It is often accompanied by, or located next 

also within the insulation foam. It must be recycled by a professional, 
competent, authorised and regulated organisation with expertise in the 
handling of refrigeration appliances. For further information, please 

5

.

0

  

DISPOSAL AT END-OF-LIFE

For further information or to obtain Genuine Spare Parts, please contact:
Interlevin Refrigeration Ltd.

West Meadow Rise,

Castle Donington, Derby, DE74 2HL.

6

.

0

  

CONTACTS

Telephone:   01332 850090

to, a bar code.

consult your local Authority.

8

Содержание EC10H

Страница 1: ...20 H S HSS PD30 H S HSS EC10H EC20 H S EC30H Interlevin Refrigeration Ltd West Meadow Rise Castle Donington Derby DE74 2HL Sales 01332 850090 Parts 01332 850190 Service 01332 850064 Email trade sales interlevin co uk Web www interlevin co uk Uploaded Jan 2016 ...

Страница 2: ...ance routines Failure to observe the instructions is unsafe and will also invalidate the guarantee the booklet in a safe place for your future reference The booklet contains mandatory safety information as well as WARNING Any refrigeration repair or any electrical work must only be 1 PD10H PD20H PD20S PD30H PD30S EC10H EC20H EC20S EC30H EC30S PD10H SS PD20H SS PD30H SS ...

Страница 3: ...ower supply 4 5 1 3 Connecting the cooler to the Power Supply 6 2 0 OPERATION 2 1 Operation of the Appliance 6 2 2 Adjustment of the temperature 6 3 0 MAINTENANCE 3 1 Lighting 7 3 2 Cleaning the interior and exterior 7 3 3 Cleaning the Condenser 7 4 0 IN THE EVENT OF A MALFUNCTION 8 5 0 DISPOSAL AT END OF LIFE 8 6 0 CONTACTS 8 2 ...

Страница 4: ...dren without supervision Do not cover the front grille or rear air vents and please observe the installation and setting up instructions described later in this manual Adequate ventilation must be ensured for the appliance Keep clear of obstruction all ventilation openings in the appliance enclosure Do not probe any openings in the cabinet and be careful not to touch any moving parts such as the f...

Страница 5: ... Unpacking and positioning before connecting to the power supply During all operations please be careful not to jolt jar bump or thump the cabinet Handle it gently and with care The refrigeration pipework is delicate and will be damaged by rough handling The appliance is heavy and therefore please carry out a risk assessment prior to beginning this operation Please cut the banding straps taking th...

Страница 6: ...nsulted malfunctions may occur including but not limited to the condensate water not draining away and the doors not functioning correctly You may adjust the appliance using the The appliance requires a minimum ventilation space at sides top and rear of 20mm The front grille must be completely unobstructed See Figure 2 Figure 2 accordance with all local laws and regulations Safety Note Please pay ...

Страница 7: ...set to chill the beverages to approximately 2 Centigrade Should you wish to alter the set point please adopt the following procedure 2 0 OPERATION 2 1 Operation of the Appliance 2 2 Adjustment of the temperature Press and hold for 4 seconds to enter the menu DEF To activate a manual defrost press this button UP Increases the parameter value DOWN Decreases the parameter value Step 1 Press and hold ...

Страница 8: ...ning the Condenser This appliance has a low maintenance condenser that is less prone to blockage than other types However it is still recommended to check that it is clean and dust free at least every three months Please adopt the following procedure or go to www cleanme eu for a demonstration enclosure Unplug from the mains power supply Step 2 Looking at the back of the appliance remove the screw...

Страница 9: ... compartment It is often accompanied by or located next also within the insulation foam It must be recycled by a professional competent authorised and regulated organisation with expertise in the handling of refrigeration appliances For further information please 5 0 DISPOSAL AT END OF LIFE For further information or to obtain Genuine Spare Parts please contact Interlevin Refrigeration Ltd West Me...