Interklima Dx Cassette Units
II-IO CCV1 R410A / Rotary / Scroll
30
ñ Ensure the ceiling is horizontally level, otherwise condensate
water cannot drain.
ñ The casing is fixed to the slab with 4 drop rods. The rods
should have two nuts and washers to lock the unit in position.
The Cassette brackets will then hook over the washers.
ñ When lifting the Cassette into position care should be taken
not to lift the unit by the drip tray, which could be damaged.
ñ Lift unit (without the air panel) with care by its four corners
only. Do not lift unit by the condensate drain discharge pipe
or by the piping connections.
ñ Incline unit (Fig.10, Fig.11, Fig.13, Fig.14) and insert it into
the false ceiling. Insert the rods into the bracket slot.
With minimum height (see table) false ceilings, it might be
necessary to remove some T brackets of the false ceiling
temporarily.
ñ Using a level guide, line up the unit with a spirit level, and
keep dimension between the body and the lower part of the
false ceiling (Fig.12 Fig.15).
ñ Line up the unit to the supporting bars of the false ceiling
tightening the nuts and counter nuts of the threaded rods.
ñ After connection of the condensate drain piping and piping
connections, check again that the unit is level.
Fig. 10
Fig.12
Fig. 11
Fig. 13
Fig.15
Fig. 14
MODEL
II-09/12/18/24CCV1
A (mm.)
3
MODEL
II 25/30/35/40/50CCV1
A (mm.)
3
Содержание II09CCV1
Страница 7: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 7 Outlook drawings 2 IO09 12CCV1...
Страница 8: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 8 IO09CCV1 IO12CCV1...
Страница 9: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 9 IO18 24CCV1...
Страница 10: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 10 IO18CCV1 IO24CCV1...
Страница 11: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 11 II25 30 35 40 50CCV1...
Страница 12: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 12 IO25CCV Y1 IO30 35CCV Y1...
Страница 13: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 13 IO40 50CCY1...
Страница 14: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 14 Refrigerant Circuit Diagram 3...
Страница 17: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 17 IO09 12 18CCV1 Outdoor Unit 1 Phase...
Страница 18: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 18 IO24CCV1 Outdoor Unit 1 Phase...
Страница 24: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 24 IO25CCY1 Outdoor 3 Phase...
Страница 25: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 25 IO30 35CCY1 Outdoor 3 Phase...
Страница 26: ...Interklima Dx Cassette Units II IO CCV1 R410A Rotary Scroll 26 IO40 50CCY1 Outdoor 3 Phase...