background image

Interflex Datensysteme GmbH   

11/23 

 

1.  Change the password. 

2.  Configure the network connection. 

3.  Restart the terminal to establish the new network connection. 

4.  Integrate the terminal into a time recording/ access control program, such as IF-6020/IF-6040, and load 

the data. Please refer to the manual of the time management/ access control program for detailed 
information. 

5.  Check the RFID reader. 

6.  Lock the housing with the mortise lock and then put the adhesive tape over the lock. 

 

14.1  Changing the Controller Password 

You can change the specified password with the Linux command 

passwd

Recommendation: Choose an encrypted password. 

root@poe-201:~ passwd 
New password: 
Retype new password: 
passwd: password updated successfully 
root@poe-201:~ 

  Please keep the new password in a safe place. If it is lost, the commands can no 

longer be accessed. The device must then be returned to the manufacturer to be reset. 

Once you have changed the password, you have to login again for it to take effect. 

 

14.2  Configuring the Network Connection 

Network connections are configured with the command 

netpar -x

 

root@poe-201:~ netpar -x 
IP address      [172.18.70.52] :172.18.12.136 
Gateway         [172.18.70.1]   : 
Netmask         [255.255.0.0]   : 
Port number     [2001]          : 
hostname        [poe-201]               : 
save changes? [y/n] y 
 
save changes to file /etc/hostname...successful 
...successful 
save changes to file /etc/network/interfaces...successful 
 
static IP address interface settings 
MAC address: 50:2D:F4:05:67:D4 
ip address : 172.18.70.52 
subnet mask: 255.255.0.0 
gateway    : 172.18.70.1 
Port number: 2001 
hostname   : poe-201 
root@poe-201:~ 

 

In the example, address 172.18.70.52 was changed to address 172.18.12.136. Other settings, such as 
Gateway, Netmask, etc. that are not to be changed can simply be confirmed by pressing the Return key. 

 

14.3  Perform a Restart 

Two commands can be used to restart the terminal: 

§

 

oc -s ( warm boot) 

§

 

oc -c (cold boot) 

You have to restart the terminal, for example, if you have changed the network address. 

The new settings have been accepted and are enabled when the master terminal of the IF-57xx shows the 
start icons. 

 

Содержание IF-57 Series

Страница 1: ...amily can read data from state of the art RFID credentials Power is supplied via a low voltage power supply unit or PoE e g injector IF 5735 0xxx records time data such as e g IN OUT bookings or absen...

Страница 2: ...ds To guarantee trouble free operation we recommend carrying out the electrical installation according to the principles of a TN S system which means using separate neutral and grounding conductors Se...

Страница 3: ...sed functional grounding is connected to PE on the 3 pin terminal strip Check if there is functional grounding on the PoE device Ground PoE devices without functional grounding via existing soldering...

Страница 4: ...Interflex Datensysteme GmbH 4 23 9 2 1 Power Supply via an External Transformer 9 2 2 Power Supply via PoE 9 2 3 RJ45 Patch Cable...

Страница 5: ...ed Cable Type 1 230 VAC power supply to optional adapter 3 x NYM 1 5 mm 2 Low voltage cable for supplying power to IF 57xx J Y ST Y 4 x 2 x 0 6 mm or Flex JZ 3 x 0 75 mm 3 Ethernet patch cable to hub...

Страница 6: ...the back panel of the housing only to an even surface If the cables are to be surface mounted a spacer is required black order no 75 5735 0001 or white order no 75 5735 0002 Recommended installation...

Страница 7: ...erminal board are connected by a 14 pin connector The power supply as well as the connection to the data lines takes place via this connector 1 RJ45 female connector 2 Connector female end The female...

Страница 8: ...LED lights up as soon as the terminal is detected by the network 5 Reset button The Reset button ends active processes and triggers a reboot restart 6 SW switch 2 The SW switch is used to set the sta...

Страница 9: ...e found in the mounting instructions no 95 10304 which are included in the delivery of the kit A service connection is possible via 1 the service interface connected through a serial USB converter ord...

Страница 10: ...signed to COM2 Using the device manager of your PC find out which COM port the IF USB serial adapter is using If your computer does not recognize the IF USB serial adapter you might have to reinstall...

Страница 11: ...anged the password you have to login again for it to take effect 14 2 Configuring the Network Connection Network connections are configured with the command netpar x root poe 201 netpar x IP address 1...

Страница 12: ...for the first time The touch screen has a layer that detects small electrical discharges such as those emitted by the human body Touch the screen with your fingertip The touch screen does not respond...

Страница 13: ...0002 not for camera terminal Interface expander as I O expansion Order number 75 5735 0003 Serial expander for connection of a serial device e g a barcode reader Order number 75 5735 0004 18 1 Interfa...

Страница 14: ...rminal Max cable length 100m PE Additional PE connection for an I O controller board COM and COM Interface to I O controller board Max cable length 100m 5VDC 5 VDC voltage supply for one I O controlle...

Страница 15: ...ntroller board for an additional IF 800 terminal This I O controller board must be installed in a secured area Power is supplied via the power transformer 8 2 IF 57xx master terminal 6 Terminal strip...

Страница 16: ...erial expander Back panel of the IF 57xx housing with a serial expander The serial expander is mounted to the back panel of the IF 57xx master terminal using 2 screws and 2 spacer sleeves Prevent shor...

Страница 17: ...cation The corresponding interface parameters are also automatically defined with the selection of the device The barcode reader interface can be used to connect and operate various barcode readers su...

Страница 18: ...rnal power supply unit requires a cable order number 90 10040 into which the power supply can be directly fed If the voltage is to be supplied by an Interface Expander then the barcode reader is conne...

Страница 19: ...wn Screw the spacer along with the metal back panel to the wall Recommended installation height 1250 mm Fasten the PoE terminal board to the metal back panel of the IF 5735 Connect the wires to the Po...

Страница 20: ...an appliance case behind the spacer This way you can variably adjust the cable length to facilitate inserting the RJ45 connector It would be beneficial if you could start the installation by connectin...

Страница 21: ...Interflex Datensysteme GmbH 21 23 18 4 1 Installation This is how the IF 57xx master terminal is mounted onto the spacer 18 4 2 Mounting 1 IF 57xx 2 Bore holes...

Страница 22: ...2mm Material Plastic Color Anthracite NCS7502B 75 5735 0005 or Silver RAL 240 70 05 75 5735 0006 19 Devices of the Series IF 57xx with WLAN or Camera Terminals of the series IF 57xx are also available...

Страница 23: ...y performing source distribution Interflex offers to provide you with a medium customarily used for software interchange containing a complete machine readable copy of the source code of the programs...

Отзывы: