Interface Technology DA-422-IRIG-2X4 Скачать руководство пользователя страница 5

HELP or ?

 (C/R) Returns list of valid keywords. 

 
Entering the keyword “Status” results in the DA-422-IRIG-2X4 displaying the current 
status including output faults, and power supply voltages. 
 
If a fault is detected, the DA-422-IRIG-2X4 will output a fault message identifying the 
fault. Every two minutes, the message will be repeated unless the fault is cleared. When 
the fault clears, the DA-422-IRIG-2X4 will output a message stating the fault has cleared. 
 
If two minute fault reminders are not desired, typing the command MASK will cause the 
DA-422-IRIG-2X4 to mask all current faults and stop reporting every two minutes. If a 
fault that was masked is cleared, the fault clear message will be sent. If the fault re-
occurs, the masking for that port will not be set and the fault will be reported every 2 
minutes. 
 
Typing the command “Unmask” will remove all fault reporting masking. 
 

Ethernet Port: 

 
The Ethernet port may be used in exactly the same way as the RS-232 port by using a 
Telnet program to connect to the IP address of the DA-422-IRIG-2X4. The IP address of 
the port may be set to a fixed address or be dynamically set through DHCP. The factory 
default is DHCP mode. The default telnet port is 10001. The default XPORT control port 
is 9999. 
 
The Ethernet port module is a Lantronix XPort module. It is recommended that the 
Lantronix web site 

WWW.lantronix.com

 be consulted to understand how to use the 

interface. A utility program from Lantronix called Device Installer (current version 
4.1.0.9) should be downloaded and used to set up the IP address. This utility program 
makes it easy to set up the parameters of the XPort device to customize it for the 
particular network application. 
 
Note that the XPort must be configured to provide a Modem Ctrl Out (DCD) signal on 
configurable pin (CP) #1 (input, active low). This is necessary for the DA-422-IRIG-
2X4to switch control ports from the RS-232 to the Ethernet port when a telnet session is 
established. 
 
When the IP address is properly configured, a telnet session may be started to 
communicate with the DA-422-IRIG-2X4. To do so on a typical windows based 
computer, select “start”, “run” then enter “CMD”, and “OK”. A cmd.exe window will 
open. In the window type “telnet 192.168.1.140 10001”. The actual IP address will of 
course have to be used (instead of 192.168.1.140) The telnet program will notify you of a 
successful connection. Pressing the “enter” key a few times should return the unit id from 
the DA-422-IRIG-2X4. 
 
 

Содержание DA-422-IRIG-2X4

Страница 1: ...chnology Group Inc Model DA 422 IRIG 2X4 RS 422 and Analog Distribution Amplifier Operation and Maintenance Manual Interface Technology Group Inc 2107 South Hwy US 1 Rockledge FL 32955 V 321 433 1165 F 321 433 0924 ...

Страница 2: ...lex outputs Using RJ 45 Connectors each separately adjustable in level Analog Frequency response or 3dB from 20 Hz to 50 kHz Output Impedance Nominal 120 ohms each output Output Level 0 to 8 V P P balanced transformer coupled DB 9 Female connector RS 232 Status Alarm Ethernet network port for Status communications Overview The model DA 422 IRIG 2X4 is designed to accept a RS 422 signal input signa...

Страница 3: ...aults are also reported via the serial port or the Ethernet port on the rear panel of the unit Faults are reported when they happen and are reported again every 2 minutes It is possible to mask out continuing faults A message is sent when the fault is cleared Operation Connect a suitable AC mains power source to the rear IEC connector Connect an RS 422 signal to the RJ 45 RS 422 input connector an...

Страница 4: ...ral other agencies Remote Status Connecting a computer running a terminal program such as Hyperterminal set up as 9600 N 8 1 allows control and status information to be passed from or to the distribution amplifier Connections for RS 232 are described in the section above Hitting Enter C R will cause the DA 422 IRIG 2X4 to respond with DA 422 IRIG 2X4 XXXX Where XXXX is the serial number of the uni...

Страница 5: ...ough DHCP The factory default is DHCP mode The default telnet port is 10001 The default XPORT control port is 9999 The Ethernet port module is a Lantronix XPort module It is recommended that the Lantronix web site WWW lantronix com be consulted to understand how to use the interface A utility program from Lantronix called Device Installer current version 4 1 0 9 should be downloaded and used to se...

Страница 6: ...dust from the cabinet when it accumulates The front panel may cleaned with a soft cotton cloth Use only a small amount of mild soap and water solution to dampen the cloth if necessary No routine checks or adjustments are required ...

Отзывы: