Owners Manual Battery Alert. (BA)
Specifications:
•
Easy installation
•
Fully programmable
•
Very low use of current
•
Automatic voltage detection 12V/24V
•
Charge reminder
•
Low voltage alarm
•
Switched alarm output
•
Compact size
•
Software fully adaptable to wishes of customers (all order quantities)
Application:
The BA has three main programs. The first two are only to be used for electrical vehicles with 12 or
24V boardsystems. These two programs remind the user that the vehicle has to be charged. The
third program is designed as a universal low voltage alarm for 12 or 24V systems. It is usable as a
start-stop regulator for generators and chargers. The last program can also be used as controller
for battery seperators.
Connection:
The BA has to be positioned as close as possible to the battery. The cable length should be 80cm
max. The cable diameter should be at least 1.5mm².
12V:
Connect the plus(+) and minus(-) of the BA directly to resp. the plus(+) and minus(-) of the
battery.
24V:
Connect the plus(+) and minus(-) of the BA directly to resp. the plus(+) and minus(-) of the
system.
The Alarm output switches the minus(-). If for example a relay is used, it needs to be connected to
the plus of the battery and the minus to the alarm output. When the BA is connected correctly the
BA will let the user hear the currently programmed values. As soon as the BA has completed this,
the programmed application will start. This is also the moment to re-program the BA.