Ethernet Jack

If the Hub is outfitted with the optional Ethernet option (ST-HUB-EN, ST-HUBD-EN), you can connect a standard CAT-5 type Ethernet 

cable to the Ethernet jack.  The opposite end of the Ethernet cable should be connected to the appropriate networking equipment, 

such as an Ethernet Switch or Router, etc.

For more information about the Ethernet communications protocol, please refer to the CueStation Network Communications 

Protocol document.

Serial Port

If the Hub is to be used with a serial device (CueServer or other host device), it can be connected in one of two different ports, a 

standard Female DB-9 connector on the front of the device as well as a 3-Position Terminal Block on the rear of the device.  Either one 

of these ports may be used, but not both at the same time (the two ports are internally connected directly together and cannot accept 

signals from two different devices simultaneously).

Null Modem Cable is required for DB-9 connection.

The following diagram shows the pinout of the Female DB-9 as well as the corresponding position of the RS-232 Terminal Block:

       

Signal

DB-9 Pin

RS-232 Port Pin

Note

Serial Transmit - Tx (to external device)

2

Tx

Connect to Receive (Rx) position on host device.

Serial Receive - Rx (from external device)

3

Rx

Connect to Transmit (Tx) pin on host device.

Ground

5

G

Connect to Ground pin on host device.

For more information about the Serial communications protocol, please refer to the CueStation Network Communications Protocol 

document.

CueStation Bus

CueStations of both the 2-Wire and 5-Wire type can be 

connected to the Hub simultaneously.  They are connected to the 

2-Position and 5-Position Terminal Blocks available on the rear of 

the unit.

Each station has a station address, which is set by a group of 

dip switches on the back of each station.  

Each station must 

have a unique address.

  Please see the documentation for each 

station type to determine the appropriate dip switch settings.

5-Wire Station Bus Wiring

The 5-Wire CueStation Bus uses a 5-conductor 22/18 AWG 

Multi-Media Cable (Belden 1502, AMX AXLINK-P or similar).  

The network topology may be run in “daisy-chain” style 

only

 

and all five conductors must be wired through without reversing 

polarity of the data lines.

A maximum of fifty (50) 5-Wire stations can be connected to a single CueStation Hub.  The maximum distance from the Hub to the 

farthest 5-Wire Station is 4000 feet (1220m).

5-Wire Station Bus Wiring Example

For more information about 5-Wire station configuration and wiring, please refer to 5-Wire CueStation Specification Sheet 

document.

S

4-Wire

RS-232

Ethernet

Station Bus

Auxiliary Ports

Bus Com

2-Wire

RS-485

V-

V+

B A

Rx

B

G

G

Tx

A

X

Y

5-Wire Station Bus

2-Wire Station Bus

Содержание CueStation ST-HUB

Страница 1: ...o 24 volts either AC or DC There are two power input jacks on the Hub a 2 1mm DC Input Jack and a 2 Position Terminal Block You can use either one but not both If the 2 1mm DC Input Jack is used it electrically disconnects the circuit from the Terminal Block input For example if a power supply outputs 630mA at 24VDC it is typically enough current to handle up to six 2 Wire or 5 Wire stations conne...

Страница 2: ...vice 3 Rx Connect to Transmit Tx pin on host device Ground 5 G Connect to Ground pin on host device For more information about the Serial communications protocol please refer to the CueStation Network Communications Protocol document CueStation Bus CueStations of both the 2 Wire and 5 Wire type can be connected to the Hub simultaneously They are connected to the 2 Position and 5 Position Terminal ...

Страница 3: ...2 Wire Station is 500 feet 150m 2 Wire Station Bus Wiring Example For more information about 2 Wire station configuration and wiring please refer to 2 Wire CueStation Specification Sheet document RS 485 Port The terminal block port marked RS 485 is not used at this time Do not connect anything to this port Configuring Stations Each station must be configured by setting a series of DIP Switches on ...

Страница 4: ...e with Hub s that have their Hub Group ID set to the same values There can be multiple combinations of CueServer Hub clusters present on the network Changing Hub Group ID in CueServer In CueServer s web interface navigate to Main User Preferences Button Settings Change the Hub Group ID field to desired value and click the Save button Changing Hub Group ID on CueStation Hub 1 Remove power from the ...

Страница 5: ...ate the desired indicator value For example the value 0 is Off the value 255 is Full White the value 139 is Fast Flashing Red at 75 brightness Bit Position Bit Value Function Parameter 7 128 LED Intensity 00 0 Intensity 25 01 64 Intensity 50 10 128 Intensity 75 11 192 Intensity 100 6 64 5 32 LED Color 000 0 Black 001 8 Red 010 16 Green 011 24 Blue 100 32 Yellow 101 40 Magenta 110 48 Cyan 111 56 Wh...

Страница 6: ...C 25 White Rev Fast 61 3D 25 White Wink 62 3E 25 White Rev Wink 63 3F 25 White On Dec Hex Intensity Color Flash 64 40 50 Black Off 65 41 50 Black Slow 66 42 50 Black Rev Slow 67 43 50 Black Fast 68 44 50 Black Rev Fast 69 45 50 Black Wink 70 46 50 Black Rev Wink 71 47 50 Black On 72 48 50 Red Off 73 49 50 Red Slow 74 4A 50 Red Rev Slow 75 4B 50 Red Fast 76 4C 50 Red Rev Fast 77 4D 50 Red Wink 78 4...

Страница 7: ...D 75 White Wink 190 BE 75 White Rev Wink 191 BF 75 White On Dec Hex Intensity Color Flash 192 C0 100 Black Off 193 C1 100 Black Slow 194 C2 100 Black Rev Slow 195 C3 100 Black Fast 196 C4 100 Black Rev Fast 197 C5 100 Black Wink 198 C6 100 Black Rev Wink 199 C7 100 Black On 200 C8 100 Red Off 201 C9 100 Red Slow 202 CA 100 Red Rev Slow 203 CB 100 Red Fast 204 CC 100 Red Rev Fast 205 CD 100 Red Win...

Отзывы: