INTER-TELPRACTICES

 256 

   

Issue 1, November 

 

The Inter-Tel 

 and GMX 256 Systems are

listed by Communication Certification Laboratory

(CCL) as meeting the Product Safety Requirements
of UL 1459, Standard for Telephone Equipment.

CCL is approved by the Occupational Health and
Safety Administration 

 as a Nationally

Recognized Testing Laboratory 

 

installation, also check the local 

 codes

for 

 information 

 the 

tion of telephone and electronic 

The following safety information is reprinted 

 UL

1459.

IMPORTANT SAFETY

INSTRUCTIONS

When using your telephone equipment, basic 
cautions should always be followed to reduce the risk of
fire, electric shock, and injury to persons, including the

following:

1. Read and understand all instructions.

2 . Follow all warnings and instructions marked on the

product.

3. Unplug this product 

 the wall outlet before

cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.

4. Do not use this product near water (for example, in a

wet basement).

5 . Do not place this product on an unstable cart, stand,

or table. The product may fall, causing serious dam-
age to the product.

6. Slots and openings in the cabinet and the back or

bottom are provided for ventilation, to protect it
from overheating; these openings must not be
blocked or covered. This product should never be
placed near or over a radiator or heat register. This

product should not be placed in a built-in installa-

tion unless proper ventilation is provided.

7. This product should be operated only from the type

of power source indicated in the manual. If you are
not sure of the type of power source to your build-
ing, consult your dealer or local power company.

8. This product is equipped with a three-wire ground-

ing type plug, a plug having a third (grounding) pin.
This plug will only fit into a grounding type power
outlet. This is a safety feature. If you are unable to

insert the plug into the outlet, contact your electri-

cian to replace your obsolete outlet. Do not defeat
the safety purpose of the grounding type plug.

9 . Do not allow anything to rest on the power cord. Do

not locate this product where the cord will be

abused by persons walking on it.

10. Do not use an extension cord with this product’s 

AC

power cord. The AC outlet for this product should
not be used for any other electrical equipment.

11. Never push objects of any kind into this product

through cabinet slots as they may touch dangerous
voltage points or short out parts that could result in a

risk of fire or electric shock. Never spill liquid of
any kind on the product.

12. To reduce the risk of electric shock, do not disas-

semble this product, but take it to a 
serviceman when some service or repair work is re-
quired. Opening or removing covers may expose
you to dangerous voltages or other risks. Incorrect
reassembly can cause electric shock when the prod-
uct is subsequently used.

13. Unplug this product from the wall outlet and refer

servicing to qualified service personnel under the
following conditions:

A. When the power supply cord or plug is dam-

aged or frayed.

B.

If liquid has been spilled into the product.

C.

If the product has been exposed to rain or wa-
ter.

D. If the product does not operate normally by fol-

lowing the operating instructions. Adjust only

those controls that are covered by the operating
instructions because improper adjustment of
other controls may result in damage and will
often require extensive work by a qualified
technician to restore the product to normal op-
eration.

E.

If the product has been dropped or the cabinet
has been damaged.

If the product exhibits a distinct change in per-
formance.

14. Avoid using a telephone (other than a cordless type)

during an electrical storm. There may be a remote
risk of electric shock from lightning.

15. Do not use the telephone to report a gas leak in the

vicinity of the leak.

SAVE THESE

INSTRUCTIONS

Page xix

Содержание GMX 256

Страница 1: ...INTEGRATED T M lMWGMX256 INSTALLATION AND FIELD MAINTENANCE MANUAL Part No 440 8074 Issue 1 November 1994 ...

Страница 2: ... station instruments described in this manual are available on both products Listed below are the station instruments that can be installed on each product IMX 256 Station Instruments GMX 256 Station Instruments l Digital Keyseta including PCDPMs 62 MDPMs l IMX AIM Keysets including dual circuit keysets l lMX non AIM Keysets 0 G X Keysets l Attendant Computer Consoles 0 Digital DSS BLF Units 0 IMX...

Страница 3: ...Part Number 440 8074 INTEGRATED TM lMwGMX256 INSTALLATION AND FIELD MAINTENANCE MANUAL Issue 1 November 1994 Inter Tel Integrated Systems inc 1994 Printed in USA ...

Страница 4: ...the telephone company has created call cost arrangements that refer to home and local area codes The home area code is the area code within which the system resides The local area codes are additional area codes that when called use the local or toll local call cost rate instead of the long distance rate Up to three local area codes can be programmed and then extended within toll restriction progx...

Страница 5: ...DISA Toll Restriction DISA lines can be given day and or night mode toll restrictions like those for individual stations except LCR Only See pages 4 38 5 106 5 111 and 5 116 SMDR Blocked DISA Calls Option A programming flag has been added to SMDR that allows blocked DISA calls to appear in the Sh4DR report See pages 4 38 4 123 and 4 124 DISA And Hunt Group Information In SMDA Summary Reports DISAc...

Страница 6: ... code generates a four digit IYIMF code that indicates the last four digits of the software part number It is used by voice processing software to ensure that the KSU software is compatible with the voice pro sing features See page 4 7 Remote Hunt Group Remove Replace The Hunt Group Remove Replace feature can be controlled from the attendant s station using the Remote Hunt Group Replace feature co...

Страница 7: ...4 SPECIFICATIONS 2 l 1 Introduction 2 2 2 Cabling And The Main Distribution Frame MDF 2 4 3 Equipment Cabinet 2 6 4 Station Instruments 2 21 5 Additional System Equipment 2 31 INSTALLATION 3 1 1 Introduction 3 2 2 System Installation Outline 3 2 3 Pre Installation Checklist 3 3 4 Station Cabling 3 6 5 Assembling The Main Distribution Frame MDF Backboard 3 9 6 Equipment Cabinet Installation 3 35 7 ...

Страница 8: ...ll Pick Up 18 Call Privacy And Privacy Release 19 Barge Keysets Only 20 Conference Galls 21 System Forwarding 22 Call Forwarding 23 Speed Dialing 24 Optional System Directory Intercom And Outside Keysets Only 25 House Phone 26 Redialing 27 Paging 28 Remove From Paging 29 Do Not Disturb 30 Cancel Miscellaneous Operations 31 Hookflash 32 Reminder Messages Keysets Only B 33 Optional Station Exchange ...

Страница 9: ...nk Programming 14 Attendants 15 Station Message Detail 16 Service TROUBLESHOOTING 1 Introduction 2 Troubleshooting Checklist 3 Light Emitting Diode LED Indications 4 Alarm Messages And Field Service Diagnostics 5 Troubleshooting Charts 6 Customer Support 7 Defective Unit Return Policy REPLACEMENT PARTS 1 Introduction 2 Ordering Procedure 3 Replacement Parts List 4 Recommended Spare Parts APPENDIX ...

Страница 10: ...RACTICES Issue 1 November 2294 IMX7GM X 256 INSTALLATION MAINTENANCE comms APPENDIX B GMX STATION INSTRUMENTS 1 Overview 2 Specifications 3 Installation 4 Features 5 Programming INDEX PAGE I B l B l B l B 5 B 10 B 10 I l Page xii ...

Страница 11: ...SS BLFUnit Inter Tel DVK DSS BLF Unit Enhanced Single Line Set ESLS Single Line Instrument SLI INSTALLATION Figure 3 l Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 Figure 3 11 Figure 3 12 Figure 3 13 Figure 3 14 Digital Keyset Modular Jack Assembly Wiring Analog Station Modular Jack Assembly Wiring Sample MDF Block Layout And Cable Assignments...

Страница 12: ...cting The Power Cable To The Telecom Motherboard Cable Connections To The Power Supply Chassis Power Supply Module Installation Equipment Cabinet Grounding Power Supply Connector Pinouts And Voltage Test Point Locations RCPU Card Digital Keyset Card DKSC Keyset Card KSC Or KSC D Single Line Card SLC Inward Dialing Card IDC Loop Ground Start Card LGC Loop Start Card LX E M Card EMC TlC Card TlC Sta...

Страница 13: ... Programming Customized Programming Report Samples Sample Board To Voice Bus Mapping Report Individual Station Programming STN Key Assignments KEY Ring Zone Programming ZONE Station Features SFEA Account Codes ACCI Do Not Disturb And Reminder Messages MESG Extensions Usernames And Feature Codes EXT Hunt Groups HUNT Misc System Wide Information MISC Page Zones PAGE Relays LAY System Forwarding Path...

Страница 14: ...s 6 3 Figure 6 2 System Troubleshooting Chart 6 14 Figure 6 3 CO Trunk Troubleshooting Chart 6 18 Figure 6 4 Feature Troubleshooting Chart 6 24 Figure 6 5 Keyset Troubleshooting Chart 6 30 Figure 6 6 Single Line Set Troubleshooting Chart 6 36 Figure 6 7 DSS BLF Unit Troubleshooting Chart 6 39 REPLACEMENTPARTS Figure 7 l Replacement Parts 7 l Figure 7 2 Recommended Spare Parts 7 5 APPENDIX A Figure...

Страница 15: ...y line service is subject to state tarif Contact the state public utility commission public service commission or corporation commission for information If this equipment causes harm to the telephone net work the telephone company will notify the cus tomer in advance that service may be temporarily discontinued But if advance notice is not practical the telephone company will notify the customer a...

Страница 16: ...perly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televi sion reception It has been type tested and found to com ply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rule Operation of this equipment in a resi dential area may cause unacceptable interference to ra dio and TV ...

Страница 17: ...unding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electri cian to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 9 Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it 10...

Страница 18: ... damages liabilities costs and ex penses arising from any act action or inaction of Buyer Although the Moss Magnuson Act should not apply in the event that it is held to apply by a court of competent jurisdiction the implied warranty of fitness for a par ticular purpose shall extend for the one year l year period from the date that the Equipment was shipped to the Buyer THIS W ISZN LlEU OF AND EXC...

Страница 19: ...dance of user friendly applica tions to meet each customer s needs Highlights of the system s design include Advanced microprocessor technology Modular easily replace able hardware with add on capabilities for optional features Flexible programming to customize many system and station features 2 1 The equipment cabinet has 16 slots for station and trunk cards The actual number of stations and trun...

Страница 20: ...an attendant equipped with a display keyset or an Attendant Computer Console to program selected system data act as the attendant for unsupervised CO re calls receive system alarm messages etc SO Keyset Circuits Equipped With Direct Sta tion Selection Busy Lamp Field SS BLF Units Digital DSWBLF Units are physically at tached to and programmed to be used with spe cific digital keysets Up to four un...

Отзывы: