Inter-m RM-8000 Скачать руководство пользователя страница 8

6

RM-8000(REMOTE MIC STATION)

Features

Convenient installation and construction without need

of ID setting.

Selection of various Chime broadcastings for MIC

broadcasting (PRE/POST).

Convenient priority broadcasting.

Adoption of  output signal level display.

Adoption of RS-422 communication method to

support a long distance.

Содержание RM-8000

Страница 1: ...RM 8000 Remote MIC Station Operation Manual ...

Страница 2: ... partie à découvert W a r n i n g Do not install this equipment in a confined space such as a book case or similar unit The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such vases shall be placed on the apparatus Worded WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING WATER AND MOISTURE Unit should not be used near water e g near a bathtub washbow...

Страница 3: ...ort Form Instructions 2 Installation Environment 4 Important Safety Instructions 4 Features 6 Front Panel 7 Rear Panel 9 Priority of Broadcasting 11 Operation 11 Connection 14 Block Diagram 15 Specifications 16 Service Procedures 17 Schematic 17 Parts List 17 Warranty 17 ...

Страница 4: ...d only be switched on later in this procedure Ensure that the AC mains power and phantom power switches are in the OFF position 2 Set all the output volume lever down to the minimum W e l c o m e A personal welcome to you from the management and employees of Inter M All of the co workers here at Inter M are dedicated to providing excellent products with inherently good value and we are delighted y...

Страница 5: ... is reached Obviously if there is distortion feedback or other cause for concern reduce the signal level of the input or the output 8 Connect one or more LM 8000 to each of the ZONE connectors as needed There is no need to set the address Connect a remote audio source or remote microphone to the LM 8000 Use the gain and BGM select button on the unit instead of the ones located on the PX 8000 The L...

Страница 6: ...ves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician...

Страница 7: ...ns which are subject to excessive dust accumulation or to vibration that could cause mechanical damage AVOID PHYSICAL SHOCKS Strong physical shocks to the unit may cause damage Handle the unit with care DO NOT OPEN THE CASE OR ATTEMPT REPAIRS OR MODIFICATIONS YOURSELF This product contains no user serviceable parts Refer all maintenance to qualified Inter M service personnel Opening the case and o...

Страница 8: ...llation and construction without need of ID setting Selection of various Chime broadcastings for MIC broadcasting PRE POST Convenient priority broadcasting Adoption of output signal level display Adoption of RS 422 communication method to support a long distance ...

Страница 9: ...ume in MIC broadcasting 2 2 2 2 MIC JACK A terminal to connect Condenser MIC Dynamic MIC can be used 3 3 3 3 IN USE LED Displays the using status of 4 Remote MIC Stations 4 4 4 4 POWER LED If power supply is applied the Power LED turns on 5 5 5 5 ALL Has toggle function as a switch to select all broadcasting areas ...

Страница 10: ...roadcasting after selecting the broadcasting area Release the button to end broadcasting During broadcast R is displayed on the relevant display of both PX 8000 and LM 8000 7 7 7 7 AREA SELECTION BUTTON Turns on if pressing the switch to select the area to broadcast and turns off if pressing it again ...

Страница 11: ...MIC and chime broadcasting 3 3 3 3 MONITOR SPEAKER VOLUME MON SPK Monitor Speaker Volume to adjust sound volume of the built in Monitor Speaker 9 RM 8000 REMOTE MIC STATION 4 3 2 1 R e a rP a n e l PIN Number 1 2 3 4 5 6 7 8 Functions Color Tx BLU Tx BLU WHT Rx GRN Rx GRN WHT GND ORG VCC ORG WHT Audio BRN Audio BRN WHT ...

Страница 12: ...tion of PX 8000 A SWITCH1 ON Chime increased by 2 tones for starting is broadcast when pressing the TALK button B SWITCH2 ON Chime increased by 4 tones for starting is broadcast when pressing the TALK button C SWITCH3 ON Chime decreased by 4 tones for ending is broadcast when releasing the TALK button D SWITCH1 2 ON Same as for SWITCH1 ON ...

Страница 13: ...g is allowed without separate ID setting 4 sets of RM 8000 can be connected If powering on buttons sequentially turn ON OFF simultaneously with power LED turned on Flashing of buttons mean defect of the unit or connection status thus check connection status and the unit RM 8000 MIC BROADCASTING Connect a MIC to the MIC input jack Both dynamic MIC and condenser MIC can be used Set the Chime Mode Sw...

Страница 14: ...orm broadcasting after checking start of Chime broadcasting using a built in monitor speaker Adjust MIC output volume of RM 8000 and input volume of PX 8000 while listening to broadcasting volume or checking the level meter R is displayed on the BGM display window of PX 8000 and LM 8000 of the broadcasting area Release the TALK button pressed to end broadcasting TALK button is on PTT method Check ...

Страница 15: ... selected during broadcasting turns off and the other IN USE LED turns on the other RM 8000 with a high priority is broadcasting in the same area RM 8000 BROADCASTING IN LINKED SYSTEM If using the PX 8000 together MIC broadcasting of the RM 8000 is not allowed to the output area of the other PX 8000 Broadcasting is allowed to only the output area of PX 8000 where the RM 8000 is connected ...

Страница 16: ...14 RM 8000 REMOTE MIC STATION Local BGM PX 8000 LM 8000 LM 8000 LM 8000 LM 8000 LM 8000 C o n n e c t i o n s ...

Страница 17: ...15 RM 8000 REMOTE MIC STATION B l o c kD i a g r a m ...

Страница 18: ...Better than 65dB T H D Less than 0 05 Serial Communication Speed 9600 bps Interface Communication Distance Maximum 300m RS 422 using UTP Cat5 Operation Temperature 10 40 Power Source DC 24V 300mA Weight SET 1 5kg 3 2lb Dimensions SET 200 W x70 H x206 D mm 7 9 W x2 8 H x8 1 D in Specifications and design subject to change without notice ...

Страница 19: ... List is available by contacting your warranty provider W a r r a n t y Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in then by locating the product type To obtain specific warranty information and available servi...

Страница 20: ... Korean company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees around the globe Inter M is well poised for further growth and expansion INTER M AMERICAS INC 13875 ARTESIA BLVD CERRITOS CA 90703 USA TEL 1 562 921 0313 FAX 1 562 921 037...