PROGRAM TIMER

5

PW-6242B

- If pushing the button at default status, it moves into MELODY scheduled content verification mode.
- If pushing the button more than 2 seconds at default status, it moves into MELODY scheduling mode.

7. AC BUTTON

It is a button used when changing the scheduling and scheduled content of AC OUTLET output. 
- If pushing the button at default status, it moves into the scheduled content verification mode of AC OUTLET

output.

-  If  pushing  the  button  more  than  2  seconds  at  default  status,  it  moves  into  the  scheduling  mode  of  AC

OUTLET output.

8. MODIFY BUTTON

It is a button used when changing the scheduled content. If pushing the button during verifying the schedule
of VOICE/MELODY/AC OUTLET output, it moves into the saved scheduling modification mode.

9. DOWN, UP BUTTON

It is a button used when selecting the scheduled content verification and various modes. 
- If pushing the button during verifying the scheduled content, it moves into previous/next scheduled content.
- If  pushing  the  button  more  than  2  seconds  during  verifying  the  scheduled  content,  it  moves  into  the

scheduled content of previous/next day. 

- It  is  used  when  selecting  the  item  of  copying/deleting  sound  source  or  scheduled  content  or  setting  the

day.

- If  pushing  the  button  more  than  2  seconds  at  default  status,  it  moves  into  communication  speed  setting

mode.

- If pushing the button during setting communication speed, communication speed value is changed.

10. OUTPUT CHANNEL DISPLAY LED

It is a LED to display the channel which is output during the playing of VOICE or MELODY sound source.
If  selecting  the  output  channel  during  scheduling,  the  selected  channel  displays  and  if  the  scheduling  is
completed, LED turns off.

11. DAY DISPLAY LED

It is a LED to display the day of current time or scheduled time. At default status, current day displays and
during the scheduling, the day of scheduled time displays.

12. DISPLAY WINDOW (VFD: VACUUM FLUORESCENT DISPLAY)

It is a window to display manipulation and operation status when manipulating each functional button. 
Current equipment status, current time, scheduled content, and progress status such as play/delete/copy are
displayed.

13. OUTPUT LEVEL VOLUME CONTROLLER

It is a volume controller to control output volume of internal melody. 

14. TIME BUTTON

It is a button used when setting the current time. 
- If pushing the button at default status, it moves into time setting mode.
- If pushing the button more than 2 seconds at default status, it moves into time error calibration mode.
- In case of time error calibration, you can select the sign of input value by pushing the button.

PW-6242B_MANUAL_141346_FOR.qxp_RFA  2017. 11. 13.  오후 4:52  페이지 5

Содержание PW-6242B

Страница 1: ...Operation Manual Program Timer PW 6242B Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference...

Страница 2: ...main readily accessible CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained...

Страница 3: ...portant Safety Instructions 2 Features 3 Package and accessory includes 3 Front Panel 4 Rear Panel 8 How to Operate 10 Application 20 PC and RS 232C Connection 21 Block Diagram 22 Specifications 23 Se...

Страница 4: ...ther apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A groundi...

Страница 5: ...orted BACK UP Power Under the setting of current time even though AC power turns off power can be maintained for about a week of time with internal Back Up power Within the time which Back Up power is...

Страница 6: ...USB memory with the device You can copy the sound source saved to USB memory Into SD Card in back side of equipment File system FAT 32 NTFS unsupported 4 OUTPUT MELODY OUTPUT BUTTON It is a button to...

Страница 7: ...heduled content or setting the day If pushing the button more than 2 seconds at default status it moves into communication speed setting mode If pushing the button during setting communication speed c...

Страница 8: ...set content or performing the function When completing the setting and pushing the button the set content is saved and it moves into the default status If pushing the button during entering the set it...

Страница 9: ...6242B If pushing the button during MELODY VOICE scheduling it moves into the item to select the sound source If pushing the button during MELODY Play operation setting it moves into the item to selec...

Страница 10: ...3 AC POWER OUTPUT2 AC OUTLET2 It is an AC power output terminal It can be used up to 500W 4 SD CARD SLOT It is a slot to mount SD CARD Basically 8GB of SD CARD is provided SD Card supported capacity...

Страница 11: ...T TERMINAL AUDIO IN FROM VOICE FILE It is a terminal to connect the audio output terminal of PV 6232A 9 SERIAL TERMINAL RS 232C It is a terminal to connect with PV 6232A Also you can add the schedulin...

Страница 12: ...f pushing HOUR MIN button once again MIN flashes on display window and input MIN using digit button Whenever pushing the button once TIME and MIN setting status converts and if pushing HOUR MIN button...

Страница 13: ...truction 3 Scheduled Track Setting After setting the scheduled time if pushing TRACK button track number flashes on display window Then input the track number using digit button You can choose up to 9...

Страница 14: ...When saving by setting MELODY schedule as the same time with already scheduled VOICE previously saved VOICE scheduled content is deleted 4 MELODY PLAY It is a function to play by selecting the desire...

Страница 15: ...uled content NO MEMORY will be displayed on display window 1 VOICE Scheduled Content Verification If pushing VOICE button LED of the button lights on and it displays from the scheduled content saved o...

Страница 16: ...ng DOWN UP button or DAY button If pushing ENTER button after setting COPY performs 2 MEMORY COPY It is a function to copy the file in USB memory to internal memory COPY from internal memory to USB me...

Страница 17: ...1 If memory space is short during COPY operation MEMORY FULL is displayed on display window In this case delete unnecessary file using DELETE function and then use 2 The content to be copied is saved...

Страница 18: ...ELTE button at the standby mode SCHEDULE MEMORY displays on display window and the selected mode flashes If pushing ENTER button after selecting MEMORY with UP DOWN button it moves into the mode to se...

Страница 19: ...button you can change before the number calibrates TIME faster and calibrates TIME slower About 1 5 seconds will be calibrated on monthly average for each stage For example if setting as 12 about 18 s...

Страница 20: ...nnecting PC with PC connecting terminal at front side of this device using USB cable portable disk is automatically recognized at PC Then PC CONNECTED is displayed to display window of this device and...

Страница 21: ...NG USB TERMINAL It is a function to copy MP3 file using USB memory connecting terminal 1 When connecting USB memory with USB memory connecting terminal at front side it is automatically recognized At...

Страница 22: ...OUT UPGRADE SOURCE 1 RS 232 SOURCE 2 EMG PANEL ADDRESS 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TERM LOAD OPEN 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 23: ...PROGRAM TIMER 21 PW 6242B PC and RS 232C Connection PC and RS 232C Connection 350mA 220V 60Hz 4 5A FUSE 250V T6 3AL N N ACCESS AC INPUT SD MEMORY PW 6242B PW 6242B Female PW 6242B...

Страница 24: ...5A DC25 6V 0A 65degree DC0 45A 60x50 AC Inlet w Fuse AC Outlet 1 AC Outlet 2 Vt 24V Fuse DC DC DC DC 5V AC_RLY 14V DC DC 14V DC DC Trhermal Fuse 500W 30W 7 P 9 7 9 AC_RLY SD Card 4GB 123779 SRAM 4Mbit...

Страница 25: ...x Maximum 15dBu Frequency Response 20Hz 20kHz Signal to Noise 20kHz LPF More than 100dB T H D 20kHz LPF less than 0 05 AC Power Output1 Maximum 500W AC Power Output2 Maximum 500W Data Retention Time M...

Страница 26: ...PROGRAM TIMER 24 PW 6242B DIMENSIONS 440 280 482 88...

Страница 27: ...by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No o...

Страница 28: ...an company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With...

Отзывы: