background image

DIGITAL PA SYSTEM

10

PSI-5120A/5240A

RS-232 PIN

Controllable operation

All functions except for some are available and you can check their detailed contents if downloading data
for control protocol.

Downloading of control protocol

Please download the protocol at the inter-m site, www.inter-m.com, SUPPORT / DOWNLOAD folder.

7. CHIME VOLUME

This is a volume to control Chime Level. 

8. PRE OUTPUT

This is the unbalanced output. This output can be used to record the signal from the unit.
The output level is not controlled by the master volume. 

9. AUX IN

This is the unbalanced input. This input can be used to connect a tape player or other sound sources.

10. MIC PRIORITY SELECT SWITCH

This is a switch to select priority of MIC broadcasting.
1) MIC 1, 2 mode : Signal from any MIC 1 or 2 input will mute all other audio signals.  
2) ALL mode : Signal from any MIC 1~5 input will mute all other audio signals. 
3) OFF mode : When this switch is in the OFF position, the MUTE function is disabled. Signal from any MIC input

will have no effect. 

11. INPUT GAIN CONTROLS (TRIM VOLUME)

These are trim volumes of each MIC inputs to control the input gain.
When adjusting the input gain, make sure that the levels are not set too high, or not it may cause noisy or distorted output.

12. PHANTOM POWER SWITCH

These switches turn the phantom power supply on or off for each channel.
When the switch is pushed, +24V DC power is supplied to the pin 2 and the pin 3 of XLR jack. Use phantom
power when you connect a condenser microphone, which requires an external power supply. 

Caution: It is safe to connect most modern dynamic microphones to the channel inputs when phantom power is

activated. However, some older ribbon microphones may be damaged by phantom power, and
certain unbalanced line level devices may malfunction or produce an audible hum when phantom
power is turned on. Use the phantom power only you use a condenser microphone.
If you press the phantom power switch when the channel volume and master volume is at the high
volume level, it may cause audible pop sound.

Pin

1

2

3

4

5

6-9

Purpose

Not Used Receive Transmit Not Used Ground Not Used

Содержание PSI-5120A

Страница 1: ...Operation Manual Digital PA System PSI 5120A 5240A...

Страница 2: ...on It has heed to be easy to disconnect the device To disconnect the device from power separate AC input cable from inlet or unplug the AC Cord CAUTION These servicing instructions are for use by qual...

Страница 3: ...Manual Auto Tuning Method 12 2 Memory Recall the Station 12 3 FM Antenna Installation 12 3 CD USB DRP Operation 13 1 Play Pause 13 2 Disc Check 13 3 REPEAT 14 4 RANDOM 14 5 GROUP UP DOWN 14 6 DISPLAY...

Страница 4: ...safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or...

Страница 5: ...as your preference CHIME Convenient to use to guide broadcasting before or after broadcasting CD COPY This function is used to copy music in a CD into inner memory or USB memory You can greatly save...

Страница 6: ...B or so but if compressing and converting it to a MP3 size of the MP3 largely reduces to 4 5MB WMA Windows Media Audio WMA is a multimedia compression method developed by Microsoft Corporation and is...

Страница 7: ...this button once you can check setting status of the current EQ mode Whenever you press the button the mode changes in order of USER 1 USER 2 USER 3 USER 4 USER5 OFF After adjusting the tone press the...

Страница 8: ...ect on the monitor speaker level 11 MASTER VOLUME Adjust the signal level of the speaker outputs 12 MIC 1 INPUT This is the balanced input Input Level 60dBV 16dBV The phantom switch must be off or not...

Страница 9: ...to playback continuously 6 COPY Button This button is used for copying a CD to USB or DRP and file copy is also available between USB and DRP 7 ENTER Button This button is used for Copy or Erase oper...

Страница 10: ...button is used to select the folder which have MP3 or WMA files 11 RANDOM Button This button is used when playback music in a disc randomly 12 REPEAT Button This button is used to playback music in R...

Страница 11: ...ith DC power supply when AC power supply is shut off 3 SPEAKER OUTPUT TERMINALS This terminal is used to connect speakers You must not connect low impedance 4 speaker to the high impedance terminal SP...

Страница 12: ...tion is disabled Signal from any MIC input will have no effect 11 INPUT GAIN CONTROLS TRIM VOLUME These are trim volumes of each MIC inputs to control the input gain When adjusting the input gain make...

Страница 13: ...edance is not less than the rated impedance indicated Rated output and impedance Caution Be sure that total impedance is not less than the rated impedance See upper chart Do not connect the low impeda...

Страница 14: ...d broadcasting is output Manual Tuning Pressing the Frequency Down or Up button once shortly enables to decrease or increase frequency and manually move to the frequency position of broadcasting stati...

Страница 15: ...k files saved in the USB memory Press the USB Function Standby status remains after automatically reading information if inserting USB memory into the front USB terminal Total file numbers to play are...

Страница 16: ...oup folder For CD music is played to the order of Number Alphabet Hangul Korean character For DRP files copied in a CD is displayed with G5 files copied in USB with G3 and REC files with G2 respective...

Страница 17: ...t mode by pressing the FUNCTION button you can find copied contents Pressing the STOP button during copying stops copying Only tracks whose play and record are completed are saved in the relevant memo...

Страница 18: ...e button to start Copy If copying is completed the function is automatically changed to the Standby mode Changing Function to the USB mode enables to find contents of copying Pressing the STOP button...

Страница 19: ...display If pressing the SEARCH UP button the starting part of the section to delete flickers Input the starting part by using the I I SKIP DOWN UP Use the SEARCH UP button to move Input the ending tr...

Страница 20: ...nt mode by pressing the EQUALIZER MODE button USER1 5 EQ OFF Select the frequency range to control by pressing the Tone button 200Hz 500Hz 1 2KHz 3KHz 8KHz Control the function to the desired level by...

Страница 21: ...Press the ENTER button to save the setting Setting is cancelled if pressing the Stop button 2 MEMORY INITIALIZATION This function is used to delete files saved in the inner memory DRP and automaticall...

Страница 22: ...DIGITAL PA SYSTEM 20 PSI 5120A 5240A Applications Applications...

Страница 23: ...r than 60dB Frequency Response 3dB 120Hz 10kHz Phantom Power 24V CD Test CD 0dB 1kHz PRE OUT S N 20KHz LPF A WTD Better than 80dB Frequency Response 3dB 100Hz 20kHz TUNER FM 22 5kHz MOD PRE OUT S N 20...

Страница 24: ...DIGITAL PA SYSTEM 22 PSI 5120A 5240A Dimensions 310 203 7 156 430...

Страница 25: ...W1 S1 S1 S2 W1 S2 W1 S2 W1 S1 S1 The example of using main body as horizontality ANGLE BKT 1 Put RACK BRACKET BKR PSI5120 from the front side of the system BRACKET separately sold 2 Secure the side of...

Страница 26: ...ns of this product exist to reflect the variations in AC power requirements throughout the world Product supplied through local sources are compatible with local AC power requirements Options No optio...

Страница 27: ...mpany but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more...

Отзывы: