background image

PublIc Address MIxIng AMPlIfIer

6

PM-236/248/260

4. InPUt VOlUME COntROllER

It is a controller to control the volume of InPuT 1~6. use by controlling to desired volume.

set the controllers of unused input terminals to minimum.

5. AUX InPUt tERMInAl (InPUt 6)

It is an Aux input terminal of InPuT 6. refer to the below picture for the cable needed to the terminal.

6. tOnE COntROllER

It is a controller to control bAss (100Hz) and Treble (10kHz). users can control to their desired tones.

7. PROtECtIOn CIRCUIt InDICAtOR

It is an indicator to display the operation status of protection circuit inside the device. When the indicator
turns on, the output is blocked.

8. MAIn VOlUME COntROllER

It is a controller to control the volumes of whole signals controlled by each input volume controller. When
turning clockwise, the volume increases.

9. SPEAKER SElECtIOn SWItCh

It  is  a  switch  to  turn  On/Off  the  signals  printing  with  five  speaker  output  terminals  or  to  turn  On/Off
whole  output  signals  with  an  All  switch.  In  the  event  of  speaker  output  On,  a  upper  indicator  of  switch
lights up.

Turn off the selection switch for unused speaker.

10. POWER SWItCh

It is a switch to turn on/off the power.

11. POWER InDICAtOR

It is an indicator to display the status of power. When the power switch is On, the indicator turns on.

12. SIREn On/OFF SWItCh

It is a switch to turn On/Off the siren. When pressing once, the siren turns On and when pressing once
again, it turns Off. While the siren is operating, a siren indicator on the right side of the switch lights up.

13. OUtPUt lEVEl InDICAtOR

It  is  an  indicator  to  indicate  the  level  of  the  signal  being  printed.  Output  level  is  indicated  with  3  -  4db
interval.

14. ChIME SWItCh

It is a switch to sound 4-note scale of chime. While chiming, a chime indicator on the left side of the switch
lights up.

Содержание PM-236

Страница 1: ...Operation Manual Public Address Mixing Amplifier PM 236 248 260...

Страница 2: ...onnect the power supply cord plug from the AC receptacle The mains plug of the power supply cord shall remain readily accessible CAUTION These servicing instructions are for use by qualified service p...

Страница 3: ...tallation environment 2 Important safety Instructions 2 Overview 3 Features 3 Contents and Accessories 4 Operation 4 Front Panel 5 Rear Panel 7 Applications 11 Block Diagram 12 Specifications 14 Servi...

Страница 4: ...ers stoves or other apparatus including amplifiers that produce heat 9 do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the...

Страница 5: ...like hospitals restaurants and schools Features Features ClASS D AMPlIFIERS hAVIng 360W 480W 600W OF OUtPUt PM 236 360W PM 248 480W PM 260 600W hIgh Z 100V 70V AnD lOW Z 4 MUltIPlE InPUtS thREE MICS...

Страница 6: ...tage before you plug into the power cord PM 236 Ac 120V or Ac 220 240V 50 60Hz PM 248 260 Ac 120 240V 50 60Hz 4 Please push the power switch then the power input led is on and the unit will be operate...

Страница 7: ...ss and hold the button for more than 2 seconds to rewind 4 button Press the button briefly to move to the next audio file Press and hold the button for more than 2 seconds to fast forward 5 rePeAT but...

Страница 8: ...he volume increases 9 SPEAKER SElECtIOn SWItCh It is a switch to turn On Off the signals printing with five speaker output terminals or to turn On Off whole output signals with an All switch In the ev...

Страница 9: ...Tel In input terminal all other input signals will be lower as set by the Tel In priority adjustment volume and the priority adjustment volume do not connect directly to the telephone network not conn...

Страница 10: ...he volume of InPuT 3 6 exT In sound when a signal is input to the InPuT 1 or InPuT 2 ex When press the switch of InPuT 2 and signal is input to InPuT 2 sound of InPuT 3 6 exT In is reduced 10 SPEAKER...

Страница 11: ...output terminal to connect when recording the sound printed from this device or using other amps in parallel It is a balanced type and pin arrangements are g 13 PRIORIty COntROl VOlUME PRIORIty MUtE I...

Страница 12: ...the connection of xlr jack euro Terminal and rcA jack Turn PHAnTOM switch Off if using the unbalanced cable 14 PRIORIty COntROl VOlUME PRIORIty MUtE This is a volume that adjust the volume of InPuT 3...

Страница 13: ...PublIc Address MIxIng AMPlIfIer 11 PM 236 248 260 Applications Applications AMP SPK MIXER...

Страница 14: ...VEL METER LED DRIVER 50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN AC IN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20...

Страница 15: ...50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20dBV INPUT 2 60 20dBV INPUT...

Страница 16: ...sensitivity Impedance MIc bAlAnce 60dbV 2k lIne bAlAnce 20dbV 2k rcA unbAlAnce 20dbV 20k 3 5 PHOne JAcK unbAlAnce 20dbV 2k Tel In bAlAnce 20 0dbV 40k exT In bAlAnce 0dbV 40k MIx OuT bAlAnce 0dbV THd...

Страница 17: ...PublIc Address MIxIng AMPlIfIer 15 PM 236 248 260 DIMEnSIOnS 88 420 318 7 419...

Страница 18: ...is available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local Ac power requirements...

Страница 19: ......

Страница 20: ...ean company but rather a global company that is truly international in scope with factories and offices in Korea and china and sales and marketing operations located in Japan europe and the u s A With...

Отзывы: