background image

DIgItAl PoWeR AMPlIfIeR

7

DPS-240D/360D/480D

6. PRIORITY VOLUME CONTROL

It  is  a  volume  control  of  PRIoRItY  INPUt  signal.  this  control  can  adjust  PRIoRItY  INPUt  signal  used  as
emergency  broadcasting.  turn  clockwise  to  turn  the  signal  level  and  counterclockwise  to  lower  the  signal
level.

It is mainly for priority broadcasting so, don’t make the VolUMe level too low.

7. OUTPUT TERMINAL

Speaker output terminal. Before connecting speakers to the unit, be sure to disconnect the AC power cable.
Make certain that the total impedance is not less than the rated impedance indicated.

Caution:

1. Make sure that the total impedance does not equal or less than the rated impedance.

2. Do not connects a speaker has lower impedance than rated impedance, it may cause the problem to unit.
3. Do not put the speaker cable close to input signal cable.

8. OUTPUT VOLTAGE SELECTOR SWITCH

this two-position switch is used to select a output voltage. (100V / 70V)

10W

10W

10W

10W

....

10W

10W

10W

10W

....

OUTPUT

CH 1

CH 2

Speaker output

Speaker Impedance

240W

100V / 41.6

Ω

70V / 20.4

Ω

360W

100V / 27.7

Ω

70V / 13.6

Ω

480W

100V / 20.8

Ω

70V / 10.2

Ω

Содержание DPS-240D

Страница 1: ...ation Manual Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference Digital Power Amplifier DPS 240D 360D...

Страница 2: ...ct the power supply cord plug from the AC receptacle The mains plug of the power supply cord shall remain readily accessible CAUTION These servicing instructions are for use by qualified service perso...

Страница 3: ...king 2 Installation environment 2 Important Safety Instructions 2 Features 3 Contents and Accessories 3 Front Panel 4 Rear Panel 6 Applications 9 Block Diagram 10 Specifications 11 Service Procedures...

Страница 4: ...ers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the...

Страница 5: ...ed RATED OUTPUT POWER VIA DC BACKUP SUPPLY output power can be maintained as AC power when DC 24V power supplied POWERFUL AND DETAILED SOUND QUALITY High S N ratio and low tHD reproduces powerful and...

Страница 6: ...will turned on During operation of DC amplifier is keep going to work even if the switch of power is turned off 2 OUTPUT LEVEL INDICATOR 1CH 2CH 3CH 4CH Indicator display of unit s output level status...

Страница 7: ...360D 480D 4 AIR VENTS the air circulation passage to prevent overheating of the device please do not obstruct the flow as air flows from front to back 5 POWER SWITCH Push on off switch When Power swi...

Страница 8: ...ther device 4 AIR VENTS Air circulation vents to prevent the device from overheating Please be careful not to block the front back of the vents 5 PRIORITY INPUT AND CONTACT CLOSURE each amplifier modu...

Страница 9: ...it be sure to disconnect the AC power cable Make certain that the total impedance is not less than the rated impedance indicated Caution 1 Make sure that the total impedance does not equal or less tha...

Страница 10: ...oWeR AMPlIfIeR 8 DPS 240D 360D 480D 9 PGM INPUT TERMINAL terminal block connector accepts the source input Please refer to the following picture about the suitable cables G G CH 2 CH 1 PGM INPUT G CH...

Страница 11: ...360D 480D Applications Applications PRIORITY VOLUME MIN MAX OUTPUT VOLTAGE 70V 100V AC POWER REMOTE CH 1 CH 2 N C G 1 COM PRIORITY SW INPUT OUTPUT G G CH 2 CH 1 PGM INPUT DPS D SERIES SPEAKER SPEAKER...

Страница 12: ...2dB 0dB PGM1 VOLUME 2 PGM PRI TOGGLE 10dB GRN SIG GRN CLIP YEL LPF 35kHz P C 12dB 12dB PRI VOLUME 0dB 0dB PRI SELECT 1 COM PRI GND PRI PRI PGM2 VOLUME DC DC DC 100 70 Vrms 100V 70V SWITCH 100V 70V SWI...

Страница 13: ...l Impedance 100V 41 6 100V 27 7 100V 20 8 70V 20 42 70V 13 6 70V 10 2 Input Sensitivity 1V 10k tHD AeS17 1 8 Power less than 0 5 S N 20kHz lPf Better than 100dB frequency Response 1W 3dB 60Hz 20kHz op...

Страница 14: ...DIgItAl PoWeR AMPlIfIeR 12 DPS 240D 360D 480D DIMENSIONS DPS 240D DPS 360D 480D 482 440 88 405 371 482 440 88 458 424...

Страница 15: ...available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Op...

Страница 16: ...company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan europe and the U S A With mo...

Отзывы: