![Inter-m DPA-4300M Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/inter-m/dpa-4300m/dpa-4300m_operation-manual_2075415016.webp)
MULTI CHANNEL POWER AMPLIFIER
14
DPA-4300M
Communication Method between devices and PCs
Communication Method between devices and PCs
1. IP ADDRESS SETUP SWITCH
It is a switch which sets up the IP Address when ETHERNET communicating.
1) Equipment ID Setup Method
- set up by using three switches in the rear panel.
- there are total three switches and first switch (1) indicates third digit, second (2) and third (3) switch
indicate fourth digit of IP Address.
- Third digit of IP Address can be set to 0~14(E) by using number one switch. 15(F) is not used.
- fourth digit of IP Address can be set to 0~255(FF) by using number two and three switches and method is
as below.
2) Example of IP ADDRESS setup
- when setting with 192 . 168 . 10 . 100
Set the third digit ‘10’ to number 1 switch ‘A(10)’.
Fourth digit ‘100’ is set to number one switch and number 2 switch is to ‘6’, and number 3 switch to 4
which is remainder. (64 )16 = (100)10 Switches are HEX Codes.
3) Caution
- when connecting one or more amps, caution not to overlap the IP address values.
When IP address are overlapped, monitoring and volume controls will not available from PC. However,
volume control with amp volume is possible.
①
②
③
192 . 168 . XX . XXX
Rotary
Value
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Decimal
Number
DPA-4300M_E_DPA-430H_E 14. 1. 3. 오후 1:43 페이지 17