Inter-m DPA-300D Скачать руководство пользователя страница 4

DIGITAL POWER AMPLIFIER

2

DPA-300D/600D, DPA-300DO/600DO

Installation

Unpacking

Unpacking 

Although  your  DPA-300D/600D,  DPA-300DO/600DO  is  neither  complicated  nor  difficult  to  operate,  we
recommend  you  take  a  few  minutes  to  read  this  brief  manual  and  familiarize  yourself  with  the  important
information regarding product features, setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never  place  this  product  in  an  environment  which  could  alter  its  performance  or  reduce  its  service  life.  Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the

apparatus  has  been  damaged  in  any  way,  such  as  power-supply  cord  or  plug  is
damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the  apparatus,  the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

S3125A

Содержание DPA-300D

Страница 1: ...Manual Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference Digital Power Amplifier DPA 300D 600D DPA 30...

Страница 2: ...ction It has heed to be easy to disconnect the device To disconnect the device from power separate AC input cable from inlet or unplug the AC Cord CAutION These servicing instructions are for use by q...

Страница 3: ...nts Unpacking 2 Installation Environment 2 Important Safety Instructions 2 Features 3 Front Panel 4 Rear Panel 5 Speaker Connection 7 Applications 8 Block Diagram 9 Specifications 13 Service Procedure...

Страница 4: ...heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wide...

Страница 5: ...duced to less than 0 03 THD with a high signal to noise S N ratio of over 103dB Advanced Protection Circuitry Advanced protection circuitry guards against overheating shorted outputs DC output overloa...

Страница 6: ...he amplifier s output signal levels SIG Green 10dB Green Clip Yellow PROTECT Red 3 VOLUME CONTROL CH1 CH2 Turn the volume controls clockwise to increase gain and counterclockwise to decrease gain 4 CO...

Страница 7: ...Air flow is front to back DO NOT block front or rear air vents 5 PRIORITY INPUT AND CONTACT CLOSURE Each amplifier module has 2 audio inputs The Primary program input PGM and Priority input PRI The p...

Страница 8: ...6 DPA 300D 600D DPA 300DO 600DO 8 OUTPUT VOLTAGE SELECTOR This two position switch is used to select a output voltage 100V or 70V 9 PGM INPUT CONNECTOR CH1 CH2 Balanced 3 pin terminal block connector...

Страница 9: ...the rated impedance indicated Caution 1 Make sure that the total impedance does not equal or less than the rated impedance 2 Do not connects a speaker has lower impedance than rated impedance It may...

Страница 10: ...DIGITAL POWER AMPLIFIER 8 DPA 300D 600D DPA 300DO 600DO Applications Applications G G CH 2 CH 1 PGM INPUT CH 2 CH 1 OUTPUT AC POWER REMOTE DPA 300D 600D...

Страница 11: ...IN 0 3dB 100 70 Vrm PROTECTION OCP OTP CLIP YEL SIG GRN 10dB GRN 100 70V SWITCH PGM PRI TOGGLE 2nd ORDER LPF FAN FAN CONTROL FAN START 65 PROTECT MORE THAN 85 TEMPERATURE DETECTION HV HV PGM1 PGM1 GND...

Страница 12: ...3dB 100 70 V PROTECTION OCP OTP CLIP YEL SIG GRN 10dB GRN 100 70V SWITCH PGM PRI TOGGLE 2nd ORDER LPF FAN FAN CONTROL FAN START 65 PROTECT MORE THAN 85 TEMPERATURE DETECTION HV HV PGM1 PGM1 GND 2 PWM...

Страница 13: ...AN FAN CONTROL FAN START 65 PROTECT MORE THAN 85 TEMPERATURE DETECTION HV HV PGM1 PGM1 GND 2 PWM PGM1 VOLUME SPEAKER OUTPUT 0dB 12dB LPF 35kHz GAIN 0 3dB PROTECTION OCP OTP CLIP YEL SIG GRN 10dB GRN 1...

Страница 14: ...GRN 100 70V SWITCH PGM PRI TOGGLE 2nd ORDER LPF FAN FAN CONTROL FAN START 65 PROTECT MORE THAN 85 TEMPERATURE DETECTION HV HV PGM1 PGM1 GND 2 PWM PGM1 VOLUME SPEAKER OUTPUT 0dB 12dB LPF 35kHz GAIN 0 3...

Страница 15: ...d Power Less than 0 1 1 3 Power Less than 0 03 S N 20kHz LPF More than 103dB Frequency Response 1W 3dB 50Hz 20kHz Operating Temperature 10 C 40 C Operating Power 120VAC 60Hz 220 240VAC 50 60Hz 24VDC P...

Страница 16: ...V 10k THD AES17 Rated Power Less than 0 1 1 3 Power Less than 0 03 S N 20kHz LPF More than 103dB Frequency Response 1W 3dB 50Hz 20kHz Operating Temperature 10 C 40 C Operating Power 120VAC 60Hz 220 24...

Страница 17: ...DIGITAL POWER AMPLIFIER 15 DPA 300D 600D DPA 300DO 600DO DIMENSIONS DPA 300D DPA 300DO 600DO 440 367 482 88...

Страница 18: ...DIGITAL POWER AMPLIFIER 16 DPA 300D 600D DPA 300DO 600DO DPA 600D 440 420 482 88...

Страница 19: ...st is available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requiremen...

Страница 20: ...pany but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more t...

Отзывы: