Inter-m A-500 Скачать руководство пользователя страница 2

MODULAR DIGITAL AMPLIFIER

Welcome

Welcome

A personal welcome to you from the management and employees of Inter-M

All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good  value,
and we are delighted you have purchased one of our products.

We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.

Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!

RISK OF ELECTRIC SHOCK

DO NOT OPEN 

CAUTION

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not
expose the unit to rain or moisture.

*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.

near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.

*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.

Connection to speakers should be performed by a skilled person.

*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.

CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing

other than that contained in the operating instructions unless you are qualified to do so."

NOTE
*
This equipment has been tested and found to comply with the limits for a Class A digital device,  pursuant to Part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against  harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense. 

This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.

This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with

an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.

Attentions: Pour prévenir les chocs électriques ne pas utiliser cette

fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.

Содержание A-500

Страница 1: ...Operation Manual Modular Digital Amplifier A 500 Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference ...

Страница 2: ...tion It has heed to be easy to disconnect the device To disconnect the device from power separate AC input cable from inlet or unplug the AC Cord CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so NOTE This equ...

Страница 3: ...ents Unpacking 2 Installation Environment 2 Important Safety Instructions 2 Features 3 Front Panel 4 Rear Panel 6 Applications 8 Block Diagram 9 Specifications 10 Service Procedures 11 Schematic 11 Parts List 11 Variations and Options 11 Warranty 11 ...

Страница 4: ...ther apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for rep...

Страница 5: ...ltage 100V 333Ω or 70V 163Ω 7 Ch modular AMP Built in 1 Ch spare AMP automatic conversion Monitoring function use of headphone Signal LED and protective LED Built in of various protective function OCP OTW OVP UVP Adoption of stable SMPS switching mode power supply Operation of DC 24V battery power during emergency ...

Страница 6: ...4 MONITOR CHANNEL DOWN UP SWITCH This is a switch to select and monitor channel of signals supplied from Z 500 and DOWN UP operation is performed within 1 ch 7 ch whenever pressing it once 5 Protective LED The red lamp turns on if inner protective circuit operates due to abnormal operation generates at AMP to inform warn of failure status 1 7 channel individually operates depending on failure of t...

Страница 7: ...f problems in the spare AMP normal broadcasting is not done even after automatic conversion 8 SPARE AMP LED The red LED turns on when the spare AMP operates The red LED turns on to display that the spare AMP operates after signal is automatically converted to spare AMP when the self temperature detection circuit and the over current protection circuit of 7 ch of AMP operate for any reason ...

Страница 8: ...is not shut out by turning this switch off 3 DC 24V INPUT TERMINAL This is a terminal to connect battery power for emergency operation If AC power as commercial power is shut off with battery power connected operation is done by automatically using battery power 4 SIGNAL INPUT CONNECTOR This is a connector where 7 ch analog signals are input from Z 500 Use 25P 600mm cables provided as accessories ...

Страница 9: ...te for channel before use by referring to printing specifications Use 2pcs of 9P terminal blocks provided as accessories of the set during connection of speaker wires A small driver with diameter of about 3mm is required Pin 1 2 3 4 5 6 7 8 9 Purpose CH1 GND CH2 CH3 GND CH4 CH5 GND CH6 Pin 10 11 12 13 14 15 16 17 18 Purpose CH7 GND NC NC CH1 CH2 GND CH3 CH4 Pin 19 20 21 22 23 24 25 Purpose GND CH5...

Страница 10: ...MODULAR DIGITAL AMPLIFIER 8 A 500 Applications Applications ...

Страница 11: ...CH 7 OUTPUT CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 SPARE SIGNAL LEDs A D A D A D 2 2 2 2 2 2 1 1 DIGITAL SIGNAL MCLK ANALOG SIGNAL INPUT 12 288MHz 13 5MHz PROTECTION LEDs MICRO CONTROLLER MODULE 1 MODULE 2 MODULE 3 AMP LPF MONITORING ENCODER SMPS AC INLET DC INPUT 29V DC GND 5V DC GND From Battery D D CON 7ch Balanced input BUFFER AMP BUFFER AMP BUFFER AMP BUFFER AMP ADC AK5384 INPUT CONNECTOR FRONT B...

Страница 12: ...ribution THD Under 0 1 AES_17 Filter Frequency Response 100Hz 20kHz 3dB at 36V Power source AC 100 120V or 220 240V 50 60Hz DC 24V Operating temperature 10 C 40 C Operating humidity 0 90 Power consumption 70W 1 8 Output Weight module 8 9kg 19 6lb Module Dimensions module 124 W x 310 H x 380 D mm 4 9 W x12 2 H x15 D in Specifications and design are subject to change without notice Specifications Sp...

Страница 13: ...ty Warranty Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in then by locating the product type To obtain specific warranty information and available service locations contact Inter M directly or the authorized Inte...

Страница 14: ...NOTE ...

Страница 15: ...NOTE ...

Страница 16: ...any but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees around the globe Inter M is well poised for further growth and expansion Inter M Americas Inc 13875 Artesia Blvd Cerritos CA 90703 USA TEL 1 562 921 0313 FAX 1 562 921 0370 Home Page ...