intensity MKA-V1200F Скачать руководство пользователя страница 3

Do not place appliances which produce open fire in 

places exposed to the air flow from the unit or under the 

indoor unit.

 

It may cause incomplete combuston or deformation of the unit 

due to the heat.

Do not install the air conditioner at any place where 

flammable gas may leak out. 

If the gas leaks out and stays around the air conditioner, a fire 

may break out. 

The appliance should not be used by children without 

supervision.

2.    PARTS  NAMES

The air conditioner consists of the indoor unit, the outdoor unit, 

the connecting pipe and the remote controller.

This function is used to operate the unit temporarily in case you 

misplace the remote controller or its batteries are exhausted. 

Two modes including AUTO and FORCED COOL can be 

selected through the TEMPORARY BUTTON on the air-in grill 

control box of the indoor unit. Once you push this button, the air 

conditioner will run in such order: AUTO, FORCED COOL,  

OFF, and back to AUTO.
AUTO

The OPERATION lamp is lit, and the air conditioner will run 

under AUTO mode. The remote controller operation is enabled 

to operate according to the received signal.

FORCED

 

COOL

The OPERATION lamp flashes, the air conditioner will turn to 

AUTO after it is enforced to cool with a wind speed of HIGH for 

30 minutes. The remote controller operation is disabled.

 

OFF

The OPERATION lamp goes off. The air conditioner is OFF 

while the remote controller operation is enabled.

1

2

3

3.    OPERATION RANGE

Use the system in the following temperature for safe and

effective operation.

NOTE

1

2

3

If air conditioner is used outside the above conditions, it 

may cause the unit to function abnormally.

The phenomenon is normal that the surface of air 

conditioning may condense water when the relative 

larger humidity in room, please close the door and 

window.

Optimum performance will be achieved within these 

operating temperature range.

In heating mode,the temperature of the inlet water must 

be  under 75

℃.

Water system operating pressuer: Max: 1.6MPa, Min: 

0.15MPa. 

4.    HINTS FOR ECONOMICAL OPERATION

The following should be noticed to ensure an economical 

operation.

Adjust the air flow louver properly and avoid direct air flow to 

room inhabitants.

Adjust the room temperature properly for a comfortable 

environment. Avoid excessive heating or cooling.

Prevent direct sunlight during cooling operation by using 

curtains or blinds.

Ventilate often. Extended use requires special attention to 

ventilation.

Keep doors and windows closed. If the doors and windows 

remain open, air will flow out of your room causing a decrease 

in the cooling or heating effect.

Never place objects near the air inlet or the air outlet of the unit. 

It may cause deterioration in the effect or stop the operation.

Set the timer .

If you don't plan to use the unit for a long time, please take the 

batteries from the remote controller. When the power is on, 

some energy will be consumed,even if the air conditioner isn't in 

operation. So please disconnect the power to save energy. 

2

owner's manual

Function indicators on indoor unit display panel

(figure 1)

    

Display panel

NOTE

This manual does not include Remote Controller 

Operations, see the<<Remote Controller Owner's 

manual>> packed with the unit for details. 

PRE-DEF indicator(cooling and heating type) 

or fan only indicator(cooling only type)

Infrared signal receiver

Operation lamp

Timer indicator

Alarm indicator

Temporary button

OPERATION  TIMER              DEF./FAN  ALARM

Frost indicator

5

If electrical appliances are disposed of in landfills or dumps,

hazardous substances can leak into the groundwater and get 

into the food chain, damaging your health and well-being

DISPOSAL

Do not dispose this product as unsor-

ted municipal waste. Collection of such waste sepa-

rately for

 

special treatment is necessary.

Do not dispose of electrical appliances as unsorted municipal 

waste, use separate collection facilities.

Contact you local government for information regarding the 

collection systems available.

Cooling operation

Heating operating

(cooling only

type without)

Mode

Temperature

Outdoor

temperature

Room

temperature

water inlet 

temperature

0°C

30°C

17°C

32°C

30°C

75°C

3°C

20°C

-15°C

24°C

0°C

43°C

Don't install the air conditioner in salty air surrounding (near 

the coast).

Содержание MKA-V1200F

Страница 1: ...Coil Of Four way Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future referen...

Страница 2: ...animals or works of art Before cleaning be sure to stop the operation turn the breaker off or pull out the supply cord Otherwise an electric shock and injury may result In order to avoid electric shoc...

Страница 3: ...AL OPERATION The following should be noticed to ensure an economical operation Adjust the air flow louver properly and avoid direct air flow to room inhabitants Adjust the room temperature properly fo...

Страница 4: ...or details on how to proceed and make sure to install cleaned air filters back in the same position Cleaning the air filter The air filter can prevent the dust or other particulate from going inside I...

Страница 5: ...emperature the indoor unit changes to fan mode when the temperature rises up the rotate speed of the fan will rise too It is same in the heating mode Symptom 4 1 Indoor unit When humidity is high duri...

Страница 6: ...roperly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures see in table 1 8 1 Troubles and causes of a...

Страница 7: ...l receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when th...

Страница 8: ...46 dB contact details MODE MKA V750R Information to identify the model s to w hich the information relation Item Symbol Value Unit Cooling capacity sensible Prated c 6 3 kW Cooling capacity latent Pra...

Страница 9: ...55 51 dB contact details MODE MKA V1500R Information to identify the model s to w hich the information relation Item Symbol Value Unit Cooling capacity sensible Prated c 4 66 kW Cooling capacity laten...

Страница 10: ...50 dB contact details MODE MKA V950F Information to identify the model s to w hich the information relation Item Symbol Value Unit Cooling capacity sensible Prated c 7 51 kW Cooling capacity latent Pr...

Страница 11: ...10 owner s manual...

Страница 12: ...16126200000028 V5 0...

Страница 13: ...a b 2 3 5 6 CE B C 7 8 C D 6 D E 8 2 Don t install the air conditioner in salty air surrounding near the coast E F Lot21...

Отзывы: