intensity IFCH306KF-1 Скачать руководство пользователя страница 3

 2 

Owner’s & Installation manual 

3. FUNCTIONS & FEATURES 

Nested in the ceiling, space-saving and noble.  
 
High capcity of cooling / heating performance, high efficiency 
and energy-saving. 
 
Adjust the indoor temperature rapidly and averagely. 
 
Low noise design. 
 
The air outlet is laid out in the way you desire.   

The air conditioner must be installed by qualified persons. 
 
When  installing  the  indoor  unit  or  its  tubing,  please  follow  this 
manual as strictly as possible. 
 
If the air conditioner is installed on a metal part of the building, it 
must  be  electrically  insulated  according  to  the  relevant 
standards to electrical appliances. 
 
When  all  the  installation  work  is  finished,  please  turn  on  the 
power only after a thorough check. 
 
Regret  for  no  further  announcement  if  there  is  any  change  of 
this manual caused by product improvement. 

To  install  properly,  please  read  this  "Owner’s  &  Installation 
manual" at first. 

2. INSTALLATION INFORMATION 

Owner’s & installation manual 

Accessory Name 

Qty. 

Sharp  

Purpose 

This manual 

4. ACCESSORIES 

Table 4-1 

DISPOSAL

˖

Do not dispose this product as unsor- 

ted municipal waste. Collection of such waste sepa- 
rately for

 

special treatment is necessary. 

Ground the air conditioner.

 

Do  not  connect  the  ground  wire  to  gas  or  water  pipes, 
lightning  rod  or  a  telephone  ground  wire. Incomplete 
grounding may result in electric shocks. 
 

Be sure to install an earth leakage breaker.

 

Failure  to  install  an  earth  leakage  breaker  may  result  in 
electric shocks.

 

 

Connect the outdoor unit wires , then connect the indoor 
unit wires.

  

You  are  not  allow  to  connect  the  air  conditioner  with  the 
power  source  until  wiring  and  piping  the  air  conditioner  is 
done. 

While  following  the  instructions  in  this  installation 
manual,  install  drain  piping  in  order  to  ensure  proper 
drainage  and  insulate  piping  in  order  to  prevent 
condensation.

 

Improper  drain  piping  may  result  in  water  leakage  and 
property damage. 
 

Install the indoor and outdoor units, power supply wiring 
and  connecting  wires  at  least  1  meter  away  from 
televisions  or  radios  in  order  to  prevent  image 
interference or noise. 

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise. 

This  appliance  is  not  intended  for  use  by  persons 
(including  children)  with  reduced  physical,sensory  or 
mental capabilities, or lack of experience and knowledge, 
unless  they  have  been  given  supervision  or  instruction 
concerning use of the appliance by a person responsible 
for their safety. 

 

Disconnect  the  power  supply  before  cleaning  and 
maintenance. Use dry cloth to clean the unit. 

Don't install the air conditioner in the following locations: 

There is petrolatum existing. 

 

There is salty air surrounding (near the coast). 

 

There is caustic gas (the sulfide, for example) existing  

in the air (near a hot spring). 

 

The Volt vibrates violently (in the factories). 

 

In buses or cabinets. 

 

In kitchen where it is full of oil gas. 

 

There is strong electromagnetic wave existing. 

 

There are inflammable materials or gas. 

 

There is acid or alkaline liquid evaporating. 

 

Other special conditions. 

CAUTION

NOTE

If  air  conditioner  is  used  outside  the  above  conditions,  it 
may cause the unit to function abnormally. 
 
The  phenomenon  is  normal  that  the  surface  of  air 
conditioning  may  condense  water  when  the  relative  larger 
humidity in room, please close the door and window. 
 
Optimum  performance  will  be  achieved  within  these 
operating temperature range. 
 
Water  system  operating  pressuer:  Max:  1.6MPa,  Min: 
0.15MPa.  

5. OPERATION RANGE

Use the system in the following temperature for safe and
effective operation.

Cooling operation 

Heating operating

(cooling only type without)

Mode 

Temperature 

Outdoor 

temperature 

Room 

temperature 

Water inlet 

temperature

0°C

̚

30°C

-15°C

̚

24°C

0°C

̚

43°C

Table 5-1 

17°C

̚

32°C

30°C

̚

80°C

3°C

̚

20°C

Accessional plastic water tray 

(

no air return box type without

˅

Содержание IFCH306KF-1

Страница 1: ...mx OWNER S INSTALLATION MANUAL IFCH304KF 1 IFCH306KF 1 IFCH308KF 1 Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep...

Страница 2: ...parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be i...

Страница 3: ...ensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or r...

Страница 4: ...the indoor unit against the following figure Install 10 pendant bolts 4 bolts The intervals of the pendant bolts are shown in the following figure 7 2 Installating the fan coil units Use the 10 pendan...

Страница 5: ...tality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire control switch see the...

Страница 6: ...h kind you need Two grooves The accessional plastic water tray 0 1 7 g i F The grooves of the accessional plastic water tray can be locked at the brim of the main water tray Please hang up the accessi...

Страница 7: ...ergo heat insulation treatment When performing the pipes connection use the rigid PVC binder and make sure that no leak exists Same as the joint of the indoor unit Be careful not to apply force at the...

Страница 8: ...ual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule The appliance shall be installed in accordance with national wiring regula...

Отзывы: