background image

InTemp® CX600 Dry Ice/CX700 Cryogenic Logger Manual 

22025-G 

InTemp CX600 Dry Ice and CX700 Cryogenic loggers are designed for cold shipment monitoring 

and have a built-in external probe that can measure temperatures as low as -95°C (-139°F) for 

the CX600 series or -200°C (-328°F) for the CX700 

series. The loggers include a protective 

sheath to prev

ent cuttin

g the cable during shipme

nt and a clip for mountin

g the probe. 

Designed for wireless communica

ti

on with a mobile device, these Bluetooth® Low Energy-

enabled loggers use the InTemp app, and InTempConnect® web-based 

softwa

re to form the 

InTemp temperature monitoring solution. Using 

the InTemp app on your phone or tablet, you 

can configure the loggers 

and then download them to share and view logger reports, which 

include logged data, excursions, and alarm info

rmation. Or, you

 can use InTempConnect to 

configure and 

download CX series loggers via the CX5000 Gateway. The InTempVerify™ app is 

also available to easily download loggers and 

automatically uploa

d reports to InTempConnect. 

Onc

e logged data is uploaded to InTempConnec

t, you can view logger configurations, build 

custom reports, monitor trip information, a

nd more. Both the CX600 and CX700 series loggers 

are available in single-use 90-day models (CX602 and CX702) or m

ultiple-use 365-day models 

(CX603 or CX703). 

Specifications 

Temperature Probe

 

CX602 & CX603 

CX702 & CX703 

Sensor Range 

-95° to 50°C (-139° to 122°F) 

-200° to 50°C (-328° to 122°F);  

To ensure insula

ti

on integrity, 

avoid 

exing the wire during 

exposure to temperatures below  

-100°C (-148°F) 

Accuracy 

±1.5°C from -95° to -40°C (±2.7°F 

from -139° to -40°F) 

±1.0°C from -40° to -10°C (±1.8°F 

from -40° to 14°F) 

±0.5°C from -10° to 50°C (±0.9°F 

from -14° to 122°F) 

±1.5°C from -200° to -90°C (±2.7°F 

from -328° to -130°F) 

±1.0°C from -90° to -10°C (±1.8°F 

from -328° to 14°F) 

±0.5°C from -10° to 50°C (±0.9°F 

from 14° to 122°F) 

Resolution 

0.013°C at 25°C (0.023°F at 77°F) 

Drift 

<0.1°C (0.18°F) per year 

NIST Calibration 

Three-point NIST calibra

ti

on, 

probe only 

CX702 and CX703: Single-point 

NIST calibr

ation

, probe only 

CX703-

UN

: Calibra

ti

on not 

included 

Cable Length 

1.5 m (4.92 

ft

Probe Dimensions 

Food-grade stainless steel probe with

 blunt tip

, 31.75 mm (1.25 inches) 

long, 4.78 mm (0.188 inches) diameter 

Logger 

 

Logger Operating Range 

-30° to 50°C (-22° to 122°F) 

Radio Power 

1 mW (0 dBm) 

Transmission Range 

Approximately 30.5 m (100 

ft

) line-of-sight 

Wireless Data Standard 

Bluetooth Low Energy (Bluetooth Smart) 

Type 

CX602 and CX702: Single use 

CX603, CX703, and CX703-

UN

: Mu

lti

ple use 

Duration 

CX602 and CX702: 90 days 

CX603, CX703, and CX703-

U

N: 

Up

 to 1 year 

Shelf Life 

U

p to 1 year 

Logging Rate 

1 second to 18 hours 

Time Accuracy 

±1 minute per month at 25°C (77°F) 

Battery 

CR2450 3V lithium, not replaceable. Ba

tt

ery for CX602 and CX702 

models lasts for dura

tion 

speci

ed when logger is used within the 1-year 

shelf life. Ba

tt

ery life for the CX603 and CX703 models is 1 year, typical 

with logging interval of 1 minute. Faster logging intervals, remaining 

connected with the InTemp app, excessive downloads, and paging may 

impact 

batt

ery life. 

(CX602 model shown) 

InTemp CX600/CX700 and 
Series Loggers 

Models: 

 

CX602, 90-day logger, 

single use 

 

CX603, 365-day logger, 

mul

tipl

e use 

 

CX702, 90-day logger, 

single use 

 

CX703, 365-day logger, 

mul

tipl

e use 

 

CX703-

U

N, 365-day logger, 

mul

tipl

e use, without NIST 

calibra

tio

Required Items: 

 

InTemp app 

 

Device with iOS 

or 

Android™ and Bluetooth 

 

 

Отзывы: