Intellitronix N3211 Скачать руководство пользователя страница 4

4-N3211                               Intellitronix                    

(rev. 09/04/2020)                          

www.intellitronix.com

 

 

The unit comes with a factory setting for an 8-cylinder engine, with activation at 5000 RPM 

Normally Open. 

The display will stay in Settings Mode until it receives a signal from the ignition 

system. To program the unit after starting the engine, shut the engine off and turn on only the 
ignition.  
 
When in Settings Mode, use push buttons on the device face to change the RPM switch setting in 
increments of 100 RPM at a time, up to 9900 RPM. The left button increases, while the right button 
decreases. Once you are at the desired setting, the LED display will stay on the RPM setting for a 
few seconds. After you have finished, the readout will continue to display your setting for a couple 
of seconds, then it will proceed to the next setting which is the 

Deactivation 

setting. After setting 

the desired ‘turnoff’ RPM, the unit will then jump to the NO and NC settings. Fi

nally, wait a few 

seconds and the device will move on to the final selection, number of cylinders. The device is 
programed for use with 1, 2, 4, 6, 8, and 12-cylinder engines. Use the left button to make your 
selection after the unit is done displaying the NO/NC status. When you are satisfied with your 
settings, start your engine and your device will start to operate automatically.  
 
 A blue LED will indicate when the switch is activated, or power is able to flow.  
 

 

 
 