SERVICE MANUAL
SMART EMS
TM
Next, looking across the other eight columns, find the one that matches the "Load Type" column you just filled in. This
column is then the function of the EMS.
Using the number at the top of the column, look in the table below to determine the settings of the three jumpers, JP1, JP2,
and JP3. A "Y" (for yes) means the jumper should be installed and an "N" (for no) means there should not be a jumper
installed.
.
At the bottom of each column is the Relay Shed Order. This determines which relays will be used for each load. The
one at the top of the column is first to be shed. The one below it will turn off next and so forth. The loads
be
wired in this order for the system to operate as desired.
Finally, the number and size of the circuit breakers should be selected to meet the needs of the installation. The breakers
can be either single or dual types. One of these breakers MUST be a 30 Amp unit to act as the Main breaker. The breakers
must be obtained and then installed in the box. (See information on breaker types later in this manual.)
RELAY WIRING TABLE
MUST
LOAD NAME
(First to shed at top)
Load
Type
1
2
3
4
5
6
7
8
A
A
A
A
A
A
D
D
A
A
A
D
D
D
A
A
A
D
D
A
A
D
A
D
D
A
D
A
D
A
D
A
Column
Number
1
2
3
4
5
6
7
8
JP1
Y
Y
Y
Y
N
N
N
N
JP2
Y
Y
N
N
Y
Y
N
N
JP3
Y
N
Y
N
Y
N
Y
N
Relay
Shed
Order
1
2
3
5
1
2
5
3
1
2
4
5
1
4
2
3
1
4
2
5
1
4
5
3
4
2
3
5
4
2
5
3