INSTALLATION AND SERVICE MANUAL
Monoplex Trio
The output channel is controlled by solid-state output devices, self-protecting FETs.
2 by 6 Pin MiniFit
(Mating Housing MOLEX 39-01-2120)
Connector Pin
Circuit Function
Connector Pin
Circuit Function
J1-1
SW 1 LED Ind
J1-7
EL Out
J1-2
SW 2 LED Ind.
J1-8
Gnd
J1-3
SW 3 LED Ind.
J1-9
MPX SW In
J1-4
SW 4 LED Ind.
J1-10
Gnd
J1-5
SW 5 LED Ind.
J1-11
Gnd
J1-6
SW 6 LED Ind.
J1-12
N. C.
2 by 3 MiniFit
(Mating Housing MOLEX 39-01-2060)
J2-1
Tx Out
J2-4
Gnd
J2-2
Rx In
J2-5
Ignition Input
J2-3
Reserved
by 6 Pin AMP Mate-N-Lok
(Mating Housing AMP MNL 640585-1)
Connector Pin
Circuit Function
Max Current
Status Indicator
J3-1
FET Output 1
15 Amp
D1
J3-2
FET Output 2
15 Amp
D2
J3-3
FET Output 3
15 Amp
D3
J3-4
FET Output 4
15 Amp
D4
J3-5
FET Output 5
15 Amp
D5
J3-6
FET Output 6
15 Amp
D6
Male Faston Stab
30 Amp
D7
Sofa Power
Outputs can be set as dimming or non-dimming. Set 6 dip switches per table.
CONNECTOR PIN-OUTS & FUSES
CAUTION -
J1
J2
J4
DIP SWITCH SETTINGS
J2-6
Parking Light Input
1
Panel Position
Ind. Lights
Fog Lights
Aux
Air Purifier
Speaker Power
TV Power
J3
Maximum continuous current output for this module is 60 Amps. Maximum in-rush current for any
channel is 70 Amps.
Position
Output / State
Function
1
Output 1(J3-1)
ON - Dimming, OFF - No Dimming
2
Output 2(J3-2)
ON - Dimming, OFF - No Dimming
3
Output 3(J3-3)
ON - Dimming, OFF - No Dimming
4
Output 4(J3-4)
ON - Dimming, OFF - No Dimming
5/6
5- Off, 6 - Off
TV Timer set to 15 Minutes Play
5/6
5 -Off 6- On
TV Timer set to 20 Minutes Play
5/6
5 - On, 6 - Off
TV Timer set to 25 Minutes Play
5/6
5- On, 6 - On
TV Timer set to 30 Minutes Play
6