background image

 

 

 

14

 

5

 

Technical specifications 

Items 

ThermalTronix 

TT-1018MDL-A-SDA

 

TT-1037MDS-A-SDA

 

  Double visual imaging system 

                                                          Thermal Camera

 

  Detector type 

Uncooled FPA microbolometer 

  Spectral range 

8~14um 

  Resolution 

384×288 

  Pixel size 

25um 

  Focal length 

18mm 

37mm 

  Field of view 

30.6°*22.9° 

14.8°*11.1° 

  Lens 

Fixed, athermalized 

  Video out 

PAL mode 

  Frame rate 

50Hz 

  Polarity 

White hot/Black hot 

  Communication 

RS485,Support PELCO-D/PELCO-P/Intellisystem 

                                                            Visual Camera 

  CCD 
  Camera 

  Resolution 

PAL:752(H)×582(V) / NTSC:768(H)×494(V) 

  Imaging device 

1/4" SONY EX-View HAD CC 

  Lens 

3.4 mm to 122.4 mm/ F1.6 to F4.5,36X 

  Horizontal resolution 

Color:550TV lines,B/W:570TV lines 

                                                Pan&Tilt 
  Angle info feedback 

Support(PELCO-D protocol) 

  Horizontal angle of rotation 

0~360° continuous rotation 

  Vertical angle of rotation 

-3°~93° 

  Horizontal rotation speed 

0.05° -150°/s 

  Vertical rotation speed 

0.05° ~100°/s 

  Preset 

128 

  Material   

Camera body in aluminium alloy, housing in 
aluminium alloy 

 

 

                                                  Physical characteristics 
  Dimensions 

Φ245(mm)×375(mm) 

  Encapsulation 

IP66 

  Weight 

7kg 

  Operation temp 

-40°C~55°C 

  Storage temp 

-40°C~70°C 

                                                                Interface 
  Video output 

PAL; 2 channels 

  Communication 

RS485 

  Protocol   

Support PELCO-D/P 

  Baud rate 

2400/4800/9600 bps 

  Power Supply 

AC24V±4V 

  Power Consumption 

50W 

 

 

Содержание ThermalTronix TT-MDL-A-SDA Series

Страница 1: ...ThermalTronix TT MDL A SDA Series Thermal Camera Specifications User Manual...

Страница 2: ...nty If the product does not operate properly in normal conditions please let us know Intellisystem Technologies will resolve the problem for free of charge The warranty period is 1 years However the f...

Страница 3: ...protect it properly during usage storage and transportation where improper use such as drop and collision will cause damage to the device Make sure that the power control connection is reliable If the...

Страница 4: ...ERATION GUIDE 6 3 1 Communication parameters 6 3 2 Thermal camera control key description 6 3 3 CCD camera keys description 7 4 Thermal imaging camera menu 7 Before operate thermal camera please set a...

Страница 5: ...e Reduction function reduce Image background noise Image enhancing function enhance the ability to detect small object CCD camera With the state of the art digital signal processing technology full di...

Страница 6: ...mera 1 AC24 Power Adapter 1 User manual 1 Packing list 1 qualification 1 2 Component names and functions 2 1 Device appearance 2 Pic 1 No Description Remark 1 Thermal Thermal camera 2 CCD Camera Inclu...

Страница 7: ...3 OPERATION GUIDE 3 1 Communication parameters Thermal camera default address PELCO D baud 2400 9600 address 2 PT system default address PELCO D baud 2400 9600 address 1 Visual camera default address...

Страница 8: ...OOM Zoom in 4 Thermal imaging camera menu 4 1 Main menu operations Before operate thermal camera please set address 2 firstly Without the menu call preset 100 to activate the main menu Enter the main...

Страница 9: ...digital zoom 6 Level X show the range of alarm From 1 to 6 default is 4 7 Seting Activate the setting secondary menu Press key FOCUS or FOCUS show the password dialogue Press FOCUS FOCUS FOCUS FOCUS...

Страница 10: ...nter refer to Pic 4 Press key LENS move the cursor press key FOCUS or FOCUS to change the value or get into the submenu where the cursor is Auto save when exit 1 COM Setup the communication parameters...

Страница 11: ...1 time during the 1 minute if working time less than 0 minute Calibrate 1 time during 2 minutes if working time between 10 and 30 minutes calibrate 1 time during 5 minutes if working time more than 3...

Страница 12: ...sor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 5 Auto save when exit 1 ID XXX Address of the IR camera 0 254 2 BauRate XXX Baud 1200 2400 4800 9600 14400 19200 38400...

Страница 13: ...ate the Mode option Press key LENS move the cursor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 6 Auto save when exit 1 Gain XXX Range 0 255 2 Bright XXX Range 0 255 3...

Страница 14: ...rmPIX XXX minimum pixels of alarm Such as alarm Number 2 so the alarm pixel is 2 2 totally 4 pixels 4 Exit Press key LENS to exit Default Level and Threshold Level 1 650 relatively temperature differe...

Страница 15: ...device 1 4 SONY EX View HAD CC Lens 3 4 mm to 122 4 mm F1 6 to F4 5 36X Horizontal resolution Color 550TV lines B W 570TV lines Pan Tilt Angle info feedback Support PELCO D protocol Horizontal angle...