background image

 

 

 

 

15

 

15

 

the temperature of the measured object. 

4.2.1.3

 

Analysis settings

 

Temperature  alarm

:  This  setting  is  valid  only  in  the  area  temperature  measurement. 

When the temperature alarm is set to "On", if the target temperature in the temperature 

measurement area exceeds or falls below the alarm temperature, the infrared gas leak 

detector  Automatic sound and color alarm. The color of the alarm is set by the "Alarm 

Color" field. 

Alarm Temperature

: Set the alarm temperature only when the temperature alarm is set 

to "On". 

Alarm Color

: When the target temperature exceeds the set alarm temperature, the color 

of the area exceeding the alarm temperature  will be displayed in the alarm  color. The 

system provides 9 colors, when set to "Auto", it will not change the original screen s color.  

Isothermal

:  displays  the  color  of  the  image  in  a  certain  temperature  range  in  the  set 

isothermal color system. The system provides 9 colors, when set to "automatic", it does 

not change the original color of the screen. 

Isothermal temperature

: the temperature of the isothermal center point. 

Isothermal  height

:  used  to  set  the  range  of  isothermal  range,  such  as  isothermal 

temperature is set to 50 

, isothermal height of 1 

, the isothermal range: 49.5 

  ~ 

50.5 

 

4.2.1.4

 

Time settings

 

Infrared gas leak detection temperature imager in a long time to put aside, because 

the internal battery power is limited, boot after the need to re-adjust the system time. 

Содержание ThermalTronix TT-607FG-HTI

Страница 1: ...INFRARED GAS DETECTION THERMAL IMAGING CAMERA ThermalTronix TT 607FG HTI User Manual...

Страница 2: ...and place it in a cool dry ventilated environment without strong electromagnetic field Avoid oil stains and all kinds of chemical contamination of the lens surface and damage the surface When finished...

Страница 3: ...g and voice playback 11 3 2 5 Output the saved file 11 4 OPERATION GUIDE 12 1 4 INTERFACE DESCRIPTION 12 2 4 MENU FUNCTIONS 13 4 2 1 Settings 13 4 2 1 1 Measurement settings 14 4 2 1 2 Temperature cor...

Страница 4: ...are the infrared radiation measurement object is converted to visual thermal images to long range Detection of sulfur hexafluoride gas and other trace leakage point and quantitatively shows the target...

Страница 5: ...4 2 Function keys and interface 2 1 Function keys Pic 2 1 1 TT 607FG HTI Top View 2 3 4 5 1 6...

Страница 6: ...5 Pic 2 1 2 TT 607FG HTI Back view Pic 2 1 3 TT 607FG HTI Bottom view 12 10 7 9 11 8 14 13...

Страница 7: ...camera manual focus 5 View Finder To see imaging 6 Adjustment Knob of view finder Adjust the sharpness in view finder 7 Power On Off Long press to turn on off the imager 8 OK Enter Select settings in...

Страница 8: ...to save file 15 Microphone For voice recording 16 LCD Screen To see imaging 2 2 Interface Pic 2 2 1 TT 607FG HTI Interface at back side 17 Mini USB Data transfer 18 Power supply DC10 15V 19 Audio out...

Страница 9: ...the camera as this photo Uninstall Press the battery latch to the right then pull out the battery Note The device can only use the standard battery or the battery may be stuck the voltage does not dam...

Страница 10: ...ry month Each charge must be greater than 50 of battery capacity 2 Charging the battery at ambient temperature of 0 40 0 ambient temperature will cause the battery charge loss 40 ambient temperature w...

Страница 11: ...n at the Cross cursor in the screen then the temperature value will be at the Top Left corner Long press A key to calibration then you can get a better measurement result 2 Menu Measurement mode Add a...

Страница 12: ...ophone when record voice 3 2 4 Imaging and voice playback 1 Menu File Open then you will see the documents management interface The files there will be in 3 formats raw jpg and m4v 2 Use Left and Righ...

Страница 13: ...12 4 Operation Guide 1 4 Interface description Infrared mode CCD mode 1 12 2 3 4 5 6 7 8 9 10 11 13 14...

Страница 14: ...nt color palette 7 Take photo Take photo 8 Auto Manual Switch auto manual calibration 9 System setting System setting 10 Preview Preview Photo Video 11 Menu Main Menu 12 Company Company Logo 13 Curren...

Страница 15: ...f any object temperature as a reference temperature 4 2 1 2 Temperature correction Specific radiating factor Because different objects have different emissivity different emissivity can be set for dif...

Страница 16: ...ea exceeding the alarm temperature will be displayed in the alarm color The system provides 9 colors when set to Auto it will not change the original screen s color Isothermal displays the color of th...

Страница 17: ...thermal image and improve the accuracy of temperature measurement Electronic magnification electronic magnification there are three options X1 X2 and X4 Laser Set the laser on and off Turning on the l...

Страница 18: ...17 4 2 1 8 Factory settings Reset to factory initial state 4 2 2 Document menu 4 2 2 1 Open a Playback jpg Record voice 40secs at mots Save Play b Playback mpeg4 m4v c Playback raw DLV original data...

Страница 19: ...o auto save 4 2 2 3 Record Note mpeg4 meet standard ISO14496 2 for play in PC DLV for analysis software 4 2 2 4 SD Choice Choose from SD1 and SD2 4 2 2 5 SD unload Please remember to unload the SD car...

Страница 20: ...2 3 Measurement mode Add point Add the temperature measurement point Add line Add the line temperature line Add area Add the regional temperature measurement area Clear Cancel all temperature Auxilia...

Страница 21: ...larm Off Alarm temperature 50 0 C Alarm color Auto Reference temperature Off Reference temperature Value 0 1 C Color Palette Auto Temperature unit C Distance unit Meter Auto calibration 60S Image sett...

Страница 22: ...21 Wrought iron Quarry faced 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Pol...

Страница 23: ...ghtness Color palette 11 color palette including iron oxide red optional rainbow black and white black and white inversion etc Measurements Temp range 40 500 Accuracy 2 or 2 reading range large value...

Страница 24: ...Laser pointer Second level 1mW 635nm red Power supply Battery type Li ion rechargeable Battery operating time 3 hours continuous operation Charging system Intelligent charge or power supply adaptor on...