Intellisystem IT-PMC-1200 P2 Скачать руководство пользователя страница 9

                                                                                               

Your Serial and Data Communications Expert 

 
 

 
 

                                                       

   

 

 

9

 

 

4. After the  warranty period,  we  will  charge accordingly 

depending on the fault or dam age. 

5. W henever there  is  a  fault, you  can  contact our technical support 

after you identify the problem and the alarm. 

 

Common Problems: 

1. PWR power supply indicator lamp not lighting  

    Cause: 

1. Power supply not properly connected.   

2. Protector tube damaged. 

3. Power input tie-line in reverse connection. 

4. Internal power supply circuit with failure. 

Solution:

 

1

. Check power switch and jack.   

2. Replace protector tube.   

3. Correct power supply line connection.   

4. Returned to the manufacturer for repair. 

 

2. FX-ACT indicator lamp not lighting  

  Cause: 

Optic fiber port link is fault.

 

Solution: 

1. Check fiber optic is link or not. 

2. Check fiber optic loss is high. 

3. Clean the connector of optic interface. 

4. Insert the well connector in place. 

5. Returned to the manufacturer for repair. 

 

3. TP1 (2)-ADD indicator lamp not lighting 

Cause: 

Ethernet port link is fault. 

Содержание IT-PMC-1200 P2

Страница 1: ...pplications The data signal converted by such high performance media converter can be transmitted up to 120Km maximum by single fiber optical cable The Converter is equipped one optic port and two RJ4...

Страница 2: ...sfer 4 Power External 5VDC input 5 Plug and play easy to installation 6 Can insert to 2U 19 14 slots Rack power external Pinout Configuration Power IT PMC 1200 P2 adopt the power supply input is 5VDC...

Страница 3: ...o negotiation can use straight through cable connect PC or server use across over connect cable Switch or HUB MDI PIN 1 2 3 6 connects opposite MID X 1 3 2 6 3 1 6 2 MDI MDI X 10Base T 100Base TX PIN...

Страница 4: ...Your Serial and Data Communications Expert 4 MDI MDI X 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 2 3 6 1 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 6 1 2 3 TX RX RX TX TX TX RX RX...

Страница 5: ...ing at 100Mbps SLOW FLASH transmitting or receiving at 10Mbps POWER OFF no POWER BRIGHT POWER is ok TP2 ADD Ethernet Port2 OFF no link BRIGHT link is ok FAST FLASH transmitting or receiving at 100Mbps...

Страница 6: ...nm Device A 1550nm Device B Power supply External 5VDC input Dimensions 94 0mm 71 0mm 26 0mm Installation support DIN Rail installation Operating temp 10 C to 65 C Storage temperature 20 to 70 C Opera...

Страница 7: ...Your Serial and Data Communications Expert 7 Wall mounting installation...

Страница 8: ...ctions according to the connection diagram 4 Check the LED Indication status and identify possible problems from the Indication LED table above Note 1 Media Converter is a sensitive electronic item pl...

Страница 9: ...Power input tie line in reverse connection 4 Internal power supply circuit with failure Solution 1 Check power switch and jack 2 Replace protector tube 3 Correct power supply line connection 4 Returne...

Страница 10: ...he rate of selected media converter 4 Check the rate of Network 5 Returned to the manufacturer for repair 4 Network packet loss Solution 1 Check Ethernet rate or full half duplex is matched or not 2 E...