LED Indicators
】
LED indictor light on the front panel of product, the function of each LED is described in the table as below.
System indication LED
LED
State
Description
P
(1~2)
ON
Power is being supplied to power input PWR input
OFF
Power is not being supplied to power input PWR input
ALM
ON
When the alarm is enabled, power or the port’s link is inactive.
OFF
Power and the port’s link is active, the alarm is disabled.
RUN
ON/OFF
System is not running well
Blinking
System is running well
Link/ACT
(1~4/G1~G2)
ON
Port connection is active
OFF
Port connection is not active
Blinking
Data transmitted
POE
(1~4)
ON
The PoE device is connected by IEEE802.3af/at standard
OFF
No PoE power output or no PoE connected PoE devices
【
Installation
】
Before installation, confirm that the work environment meet the installation require, including the power need s and abundant space. Whether it is
close to the connection equipment and other equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Power: 44~57VDC power input
5. Environment: Working temperature: -40
~
75
℃
Storage Temperature: -40
~
85
℃
Relative humidity: 5%
~
95%
DIN Rail Installation
In order to use in industrial environments expediently, the product adopt 35mm DIN-Rail installation, the installation steps as below:
1.
Examine the DIN-Rail attachment
2.
Examine DIN Rail whether be firm and the position is suitability or not.
3.
Insert the top of the DIN-Rail into the slot just below the stiff metal spring.
4.
The DIN-Rail attachment unit will snap into place as shown below.