FUNDAMENTAL SYSTEM
MONITOR
CAMERA
The Auto Shutter Control Switch is set to
"
O N
"
position at the factory before the
camera is shipped. With the Auto Shutter Control Switch is in the
"OFF"
position, adjust aperture of the lens to obtain the most desirable aperture setting.
Please adjust the focus on the lens to obtain the best quality picture on the
monitor. After performing the above process, if Auto Shutter is required, please
turns the switch to
"
O N
"
position.
(d)
Back Focus Adjustment: Depending on the lens used, proper focus may not be
obtained even by performing lens focus adjustment. In this case, back focus
adjustment is needed. First, set the focus ring of the lens to the infinite position
and take a picture at a distance of 20 meter or more from the camera. Loosen the
lens mount with the
6
angle wrench, and turn the mount and the lens at the same
time
so that the picture on the monitor is in focus. Then secure screw firmly at
the point where the subject is in focus.