Intellinet 780100 Скачать руководство пользователя страница 4

4

 

MODULAR CABLE TEST

To test RJ11 and RJ12 cables, follow the same instructions as the Loopback and Remote Test above. Refer 

to the top section of Table A and Table B on the next page.

BASIC OPERATING INSTRUCTIONS

The Loopback and Remote test instructions describe the basic way to use both the master and remote 

units to read a cable’s wiring. Expanded instructions for other test types exist below.

1

2

3

4

5

To perform a loopback test, plug the two ends of the cable into the corresponding jacks on the Main 

tester (A and B).  

To test patch-panel or wall-plate connections, connect a cable from the Main tester jack (A or B) to the 

input ports of the panel or plate, and then connect the Remote Terminator (C) to the output ports of the 

panel or plate you wish to test. 

Turn on the unit. 

 Set the toggle to AUTO for the tester to quickly cycle through the pins and their corresponding LEDs. 

Set the toggle to MANUAL and repeatedly press the TEST button to advance through pins. 

Review the LED results below for the status of the cable’s wiring on the next page in the section “Pin out 

Indicator.”

LOOPBACK AND REMOTE TEST

10Base-T Cable Test

Loopback Test

Remote Test

10Base-2 Cable Test

Plug the RJ45 connectors into the jacks on the tester. Then connect the BNC adapter cables on both ends 

of the BNC connectors. Follow the instructions above from steps 3 to 5. To correct cable gender issues, 

use the included adapters. 

Note: The center pin on the BNC connector should be read on LED #1 and the shielding pin should be 

read on LED #2. Intellinet recommends reading the LED scan through Manual mode by pressing the Test 

button, F.

1   2   3   4   5   6   7    8   G

BNC center pin

BNC shielding pin

Содержание 780100

Страница 1: ...Network Modular Cable Tester User Manual Model 780100 INT 780100_UM 1216_Rev 5 01 intellinetnetwork com ...

Страница 2: ...s should be kept in mind while using this tester for the protection of both the user and the device itself Read all instructions before using this device Do not place the device in direct sunlight or in hot environments Do not modify this tester Do not open this tester for maintenance without first disconnecting it from all external circuitry Do not apply voltage or current to any of the tester s ...

Страница 3: ...k Remote Tester RJ45 jack Auto Maunual Test switch Power switch Test switch for Manual scan LED Display for Sourcing End Jack A LED Display for Receiving End Jack B LED Display for Receiving End same as Jack B Battery compartment PRODUCT PROFILE A B C E D F G H I J ...

Страница 4: ...anel or plate you wish to test Turn on the unit Set the toggle to AUTO for the tester to quickly cycle through the pins and their corresponding LEDs Set the toggle to MANUAL and repeatedly press the TEST button to advance through pins Review the LED results below for the status of the cable s wiring on the next page in the section Pin out Indicator LOOPBACK AND REMOTE TEST 10Base T Cable Test Loop...

Страница 5: ...eing tested Table B shows examples of what the resulting lit and unlit LEDs mean for wiring status in this example for RJ45 cables 1 2 3 4 5 6 7 8 G Connected 1 2 3 4 5 6 7 8 G Disconnected 1 2 3 4 5 6 7 8 G Shorted 1 2 3 4 5 6 7 8 G Miswired A B VISUAL BASIC OPERATING INSTRUCTIONS 1 2 3 4 5 6 7 8 G RJ11 RJ12 1 2 3 4 5 6 RJ45 A B ...

Страница 6: ...6 NOTES ...

Страница 7: ...be taken to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate waste handling of this product If your equipment contains easily removable batteries or accumulators disposeoft...

Страница 8: ... IC Intracom All rights reserved Intellinet is a trademark of IC Intracom registered in the U S and other countries ...

Отзывы: