Intellijel Plonk Скачать руководство пользователя страница 13

  

 

 

Plonk​ ​Manual​​ ​​

v1.01 

 

 

 

14.

CONFIG

 

Button

 

​​

-

 

Accesses

 

the

 

​​

CONFIG

​​

 

menu. 

15.

X

 

Button

 

​​

-

 

Accesses

 

the

 

​​

VAR

 

X

​​

 

assignment

 

screen.

 

This

 

is

 

described

 

in

 

more

 

detail

 

in 

the

 

​​

VAR

 

X

 

and

 

Y

 

Destinations

 

section. 

16.

Y

 

Button

 

​​

-

 

Accesses

 

the

 

​​

VAR

 

Y

​​

 

assignment

 

menu.

 

This

 

menu

 

behaves

 

the

 

same

 

as

 

the 

VAR

 

X

​​

 

menu,

 

but

 

for

 

the

 

​​

Y

​​

 

input. 

Inputs

 

and

 

Outputs 

A.

X

​​

 

-

 

CV

 

offset

 

for

 

the

 

​​

VAR

 

X

​​

 

destination.

 

The

 

accompanying

 

attenuverter

 

can

 

be

 

used

 

to 

scale

 

and

 

flip

 

the

 

incoming

 

voltage.

 

Range

 

of

 

±5

 

V.

 

See

 

the

 

​​

VAR

 

X

 

and

 

Y

 

Destinations

 

section

 

for

 

more

 

details. 

B.

MOD

 

​​

-

 

CV

 

input

 

for

 

the

 

​​

MOD

​​

 

destination

 

modulation.

 

The

 

accompanying

 

attenuverter 

can

 

be

 

used

 

to

 

scale

 

and

 

flip

 

the

 

incoming

 

voltage.

 

Range

 

of

 

±5

 

V.

 

If

 

the

 

selected 

destination

 

is

 

triggered

 

by

 

a

 

gate

 

then

 

any

 

voltage

 

above

 

1.5

 

V

 

is

 

sufficient. 

C.

DECAY

 

​​

-

 

CV

 

offset

 

for

 

the

 

​​

DECAY

​​

 

control.

 

The

 

accompanying

 

attenuverter

 

can

 

be

 

used 

to

 

scale

 

and

 

flip

 

the

 

incoming

 

voltage.

 

Range

 

of

 

±5

 

V. 

D.

Y

 

​​

-

 

CV

 

offset

 

for

 

the

 

​​

VAR

 

Y

 

​​

destination.

 

Behaves

 

the

 

same

 

as

 

the

 

​​

X

​​

 

input,

 

but

 

for

 

​​

VAR 

Y

.

 

E.

PITCH

 

​​

-

 

1

 

V/octave

 

pitch

 

input.

 

Summed

 

with

 

the

 

position

 

of

 

the

 

​​

PITCH

​​

 

knob.

 

Range

 

of 

±5

 

V.

 

The

 

pitch

 

is

 

updated

 

only

 

while

 

the

 

​​

TRIG

​​

 

input

 

is

 

high. 

F.

TRIG

 

​​

-

 

Triggers

 

the

 

exciter

 

in

 

response

 

to

 

a

 

gate.

 

The

 

gate

 

must

 

have

 

a

 

duration

 

of

 

at 

least

 

one

 

millisecond

 

to

 

be

 

detected

 

by

 

the

 

module.

 

If

 

the

 

preset’s

 

noise

 

envelope

 

is

 

set 

to

 

AHR,

 

the

 

envelope

 

remains

 

in

 

the

 

hold

 

stage

 

for

 

the

 

duration

 

of

 

the

 

gate. 

G.

VEL

 

​​

-

 

Velocity

 

input.

 

Range

 

of

 

+5

 

V

 

and

 

normalled

 

to

 

+5

 

V.

 

Controls

 

the

 

velocity

 

or 

volume

 

of

 

the

 

sound,

 

depending

 

on

 

the

 

​​

VEL

 

Mode

​​

 

setting

 

in

 

the

 

​​

CONFIG

​​

 

menu.

 

See

 

the 

VEL

 

Mode

 

section

 

for

 

more

 

details. 

H.

OUT

 

​​

-

 

Mono

 

audio

 

output. 

 

 

 

 

Page

 

12 

Содержание Plonk

Страница 1: ...Plonk Manual v1 01 Plonk Physical Modeling Percussion Synthesizer...

Страница 2: ...rt Installing Your Module Quick Start Front Panel Controls Inputs and Outputs Parameter Menus Pitch Parameters Octave Quantize Exciter Parameters Mallet Noise Mix Mallet Stiffness Noise Density Noise...

Страница 3: ...Tone Resonator Inharmonicity Resonator Pitch Envelope Amount Resonator Pitch Envelope Time Polyphony VAR X and Y Destinations MOD Destinations Choke Resonator Noise Both Preset Step Randomize Morph C...

Страница 4: ...Plonk Manual v1 01 Downloading Presets to a Computer Uploading Presets from a Computer Calibration Technical Specifications Firmware Changelog 1 0 July 20 2017 Page 3...

Страница 5: ...t being struck which vibrates resonates and creates the body of a sound Plonk offers several types of resonators beam marimba drumhead membrane plate and string Plonk provides numerous parameters that...

Страница 6: ...nd banks of patches may be transferred via MIDI System Exclusive over Plonk s built in mini USB port to facilitate offline storage by programs or websites that support this capability Plonk was develo...

Страница 7: ...apacity or upgrade your power supply You will also need to ensure you have enough free space hp as well as free power headers in your case to fit the new module You can use a tool like ModularGrid to...

Страница 8: ...s that serve other purposes so ensure the cable is connected to the right one The other end of the cable with a 16 pin connector connects to the power bus board of your Eurorack case Ensure the red st...

Страница 9: ...seated on both ends and that all the pins are correctly aligned If the pins are misaligned in any direction or the ribbon is backwards you can cause damage to your module power supply or other modules...

Страница 10: ...Run the sequencer you should hear the Plonk make noise 4 If your sequencer has a secondary CV output connect it to the VEL input for velocity control Switch between sounds 1 Connect a sequencer track...

Страница 11: ...Plonk Manual v1 01 Front Panel Page 10...

Страница 12: ...odulating the VAR X destination 8 Y Knob Bipolar control for manually modulating the VAR Y destination 9 LOAD Button Accesses the LOAD menu which is used for loading presets from the onboard flash mem...

Страница 13: ...by a gate then any voltage above 1 5 V is sufficient C DECAY CV offset for the DECAY control The accompanying attenuverter can be used to scale and flip the incoming voltage Range of 5 V D Y CV offset...

Страница 14: ...se The mallet is a momentary impulse while the noise is white noise that can be shaped by a lowpass filter highpass filter and amplitude envelope The filters are applied in series so together they can...

Страница 15: ...ate envelope and filter settings a noise density between 50 and 100 can be good for bowed sounds or snares Noise Lowpass Cutoff Sets the cutoff frequency of the lowpass filter applied to the white noi...

Страница 16: ...a drumhead will be bunched closer together The material of the resonator will have an effect on the relative decay of the partials while the position at which it is excited will have an effect on the...

Страница 17: ...he partials Perceptually this parameter affects the object s material Depending on the resonator type lower values may evoke wood nylon or plastic while higher values may evoke metal or glass Resonato...

Страница 18: ...n the modulation destination selection screen you can push the X or Y button a second time to set the DEPTH of the respective control The DEPTH allows you to configure how much the full range of the m...

Страница 19: ...5 will select another preset in the range proportional to the amount of voltage applied Selecting a preset in this way is subject to the following conditions All exciter and object parameters will be...

Страница 20: ...esonator type assigned to the destination preset However all other resonator and exciter parameters do morph CONFIG Settings Gain Adjusts the overall gain of the current patch from 20 dB to 12 dB This...

Страница 21: ...other modules in a larger system its panel knobs are always live That is when you recall a preset every parameter is set to its saved value however any value presently under the control of a front pan...

Страница 22: ...will be indicated by a star next to the preset number Saving To enter the preset save menu click the SAVE button Turn the ENCODER to find a slot in which to save the current module settings The last l...

Страница 23: ...ck the CONFIG button Turn the ENCODER till the display reads Send Presets Click the ENCODER If you haven t yet connected the USB cable to the back of the module the display will read Connect USB Once...

Страница 24: ...zer to the PITCH input Ensure nothing is connected to any of the other inputs 5 Set the voltage source to 0V The number on the display should be around 52000 6 Click the ENCODER The screen will indica...

Страница 25: ...Plonk Manual v1 01 Firmware Changelog 1 0 July 20 2017 Initial release Page 24...

Отзывы: