Once   connected,   the   cabling   between   the   module   and   power   supply   should   resemble   the   picture   
below:   

 

Before   reconnecting   power   and   
turning   on   your   modular   system,   
double   check   that   the   ribbon   cable   
is   fully   seated   on   both   ends   and   
that   all   the   pins   are   correctly   
aligned.   If   the   pins   are   misaligned   
in   any   direction   or   the   ribbon   is   
backwards   you   can   cause   damage   
to   your   module,   power   supply,   or   
other   modules.   

 

After   you   have   confirmed   all   the   
connections,   you   can   reconnect   the   
power   cable   and   turn   on   your   
modular   system.   You   should   

immediately   check   that   all   your   modules   have   powered   on   and   are   functioning   correctly.   If   you   
notice   any   anomalies,   turn   your   system   off   right   away   and   check   your   cabling   again   for   mistakes.   

 

 

 

 

 

 

Dual   VCA   1U   Manual 

 

 

Содержание Dual VCA 1U

Страница 1: ...Dual VCA 1U Dua Stereo Linear Voltage Controlled Amplifier Manual English Revision 2021 08 03...

Страница 2: ...TABLE OF CONTENTS COMPLIANCE 2 INSTALLATION 3 Before You Start 3 Installing Your Module 4 FRONT PANEL 6 TECHNICAL SPECIFICATIONS 7 Dual VCA 1U Manual 1...

Страница 3: ...ply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is oper...

Страница 4: ...specified 12V current draw for all modules including the new one Do the same for the 12 V and 5V current draw The current draw will be specified in the manufacturer s technical specifications for each...

Страница 5: ...indicate the 12V pins Some may be labelled with 12V a white stripe next to the 12V pins the words red stripe or some combination of these Additionally some modules may have shrouded headers thus prev...

Страница 6: ...f the pins are misaligned in any direction or the ribbon is backwards you can cause damage to your module power supply or other modules After you have confirmed all the connections you can reconnect t...

Страница 7: ...t IN A 1 Voltages above 5V increase the gain with a 10 V CV input resulting in a maximum gain of 6 dB The amount of voltage present at CV A 3 is indicated by the brightness of the LED Common CV source...

Страница 8: ...TECHNICAL SPECIFICATIONS Dual VCA 1U Manual 7 Width 8 hp Maximum Depth 29 mm Current Draw 37 mA 12V 40 mA 12V...