background image

 

 

 

 

INSTALLATION   

 

Intellijel   Eurorack   modules   are   designed   to   be   used   with   a   Eurorack-compatible   case   and   power   
supply.   We   recommend   you   use   Intellijel   cases   and   power   supplies.   

 

Before   installing   a   new   module   in   your   case,   you   must   ensure   your   power   supply   has   a   free   power   
header   and   sufficient   available   capacity   to   power   the   module:   

 

● Sum   up   the   specified   +12V   current   draw   for   all   modules,   including   the   new   one.   Do   the   same   for   

the   -12   V   and   +5V   current   draw.   The   current   draw   will   be   specified   in   the   manufacturer's   
technical   specifications   for   each   module.   

 

● Compare   each   of   the   sums   to   specifications   for   your   case’s   power   supply.   

 

● Only   proceed   with   installation   if   none   of   the   values   exceeds   the   power   supply’s   specifications.   

Otherwise   you   must   remove   modules   to   free   up   capacity   or   upgrade   your   power   supply.   

 

You   will   also   need   to   ensure   your   case   has   enough   free   space   (hp)   to   fit   the   new   module.   To   
prevent   screws   or   other   debris   from   falling   into   the   case   and   shorting   any   electrical   contacts,   not   
leave   gaps   between   adjacent   modules,   and   cover   all   unused   areas   with   blank   panels.   Similarly,   do   
not   use   open   frames   or   any   other   enclosure   that   exposes   the   backside   of   any   module   or   the   power   
distribution   board.   

 

You   can   use   a   tool   like    

ModularGrid  

  to   assist   in   your   planning.   Failure   to   adequately   power   your   

modules   may   result   in   damage   to   your   modules   or   power   supply.   If   you   are   unsure,   please    

contact   

us  

  before   proceeding.   

 

Installing   Your   Module   

 

When   installing   or   removing   a   module   from   your   case   
always   turn   off   the   power   to   the   case   and   disconnect   
the   power   cable.   Failure   to   do   so   may   result   in   
serious   injury   or   equipment   damage.  

Ensure   the   10-pin   connector   on   the   power   cable   is   
connected   correctly   to   the   module   before   proceeding.   
The   red   stripe   on   the   cable   must   line   up   with   the   
-12V   pins   on   the   module’s   power   connector.   The   pins   
are   indicated   with   the   label   -12V,   a   white   stripe   next   
to   the   connector,   the   words   “red   stripe”,   or   some   
combination   of   those   indicators.    

  

Most   modules   will   come   with   the   cable   already   
connected   but   it   is   good   to   double   check   the   

 

 

Dixie   II+   Manual 

 

 

Содержание Dixie II+

Страница 1: ...Dixie II Full Featured Triangle Core Analog VCO LFO Manual English Revision 2021 08 01 ...

Страница 2: ...TABLE OF CONTENTS COMPLIANCE 2 INSTALLATION 3 Installing Your Module 3 OVERVIEW 5 Front Panel 5 Controls 5 Inputs Outputs 6 TECHNICAL SPECIFICATIONS 7 Dixie II Manual 1 ...

Страница 3: ...ly with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfere...

Страница 4: ...g into the case and shorting any electrical contacts not leave gaps between adjacent modules and cover all unused areas with blank panels Similarly do not use open frames or any other enclosure that exposes the backside of any module or the power distribution board You can use a tool like ModularGrid to assist in your planning Failure to adequately power your modules may result in damage to your m...

Страница 5: ...ted the cabling between the module and power supply should resemble the picture below Before reconnecting power and turning on your modular system double check that the ribbon cable is fully seated on both ends and that all the pins are correctly aligned If the pins are misaligned in any direction or the ribbon is backwards you can cause damage to your module power supply or other modules After yo...

Страница 6: ...his switch selects the mode of the FM1 input between linear and exponential response 3 FINE When in VCO mode this knob functions as a fine adjustment for the tuning frequency The range is approximately 6 semitones from the centre position When the oscillator is in LFO mode the range of the knob is much higher approximate 7 octaves 4 VCO LFO This switch switches the Dixie II between VCO and LFO mod...

Страница 7: ...SE output The range is 5 V Note that the width can go down to 0 and up to 100 at which point no wave will be produced D 1V OCT Primary pitch voltage control input E SYNC When the input waveform crosses zero the oscillator is also reset to zero F FLIP This input functions similarly to the SYNC input except that instead of resetting the oscillator to zero it flips the direction of travel G SINE Sine...

Страница 8: ...TECHNICAL SPECIFICATIONS Dixie II Manual 7 Width 8 hp Maximum Depth 40 mm Current Draw 60 mA 12V 70 mA 12V ...

Отзывы: