Intelligent Charging Limited TS2X020 Скачать руководство пользователя страница 16

T

S2X020 : Twin Channel Battery Charger

Operators Manual

 10 

Product Warranty

Your Intelligent Charging Limited product is guaranteed against faulty workmanship materials
and malfunction for a period of 12 months from the date of purchase, unless agreed otherwise
by Intelligent Charging Limited. Within this warranty period Intelligent Charging Limited will
undertake to repair or replace the product proved to be faulty.

We recommend you keep all packaging for the duration of the 12 month warranty, after which
you should dispose of all waste packaging in accordance with your local legislation 

Products which have become faulty within the 12 month warranty period must be returned to
Intelligent   Charging   Limited,   where   Intelligent   Charging   Limited   will   then   investigate   the
warranty claim.

Intelligent   Charging   Limited   products,   when   properly   used,   will   render   excellent   service.
Therefore, users must read the User Manual and any other literature supplied with the product
carefully, and fully comply with all procedures shown in the literature and product training /
familiarisation   sessions,   as   misuse   or   failure   to   follow   the   instructions   may   render   this
warranty void.

This   warranty   is   not   transferable   and   excludes   routine   maintenance,   consumables,   parts
subject to normal wear and tear, service maintenance kits and damage caused by misuse or
negligence.   Warranty   claims   attributable   to   improper,   or   careless,   use   or   handling,   and   to
normal wear, are excluded from this warranty.

Intelligent Charging Limited only obligation shall be to repair or replace such products that
have proved to be faulty. Intelligent Charging Limited shall not be liable for any injury, loss or
damage, direct or consequential, arising out of the use, or the inability to use the product. The
customer shall determine the suitability of this  product for its intended use, and the customer
assumes all risks and liability whatsoever in connection herewith.

Intelligent Charging Limited reserves the right to improve or modify this product

without prior notice.

Doc: DWG1021-10-R2 TS2X020 Operators manual.odt

Page 16 of 16

Copyright Material of Intelligent Charging Limited © 2015

Printed On : 14/06/17

Содержание TS2X020

Страница 1: ...Battery Charger Operators Manual Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 1 of 16 Copyright Material of Intelligent Charging Limited 2015 Printed On 14 06 17 TS2X020 TWIN CHANNEL BATTERY CHARGER OPERATORS MANUAL ...

Страница 2: ... 10 5 Charging Two Batteries Simultaneously 11 6 Hints And Tips 12 7 Service And Maintenance 14 7 1 Calibration 14 7 2 Cleaning 14 8 Specifications 15 9 Product Disposal Instructions 16 10 Product Warranty 17 1 Manual Revision History Rev Date Description 1 11 10 2000 First Written 2 22 02 2010 Written for new operational modes Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 2 of 16 Copyright ...

Страница 3: ... by a constant current mode with the output voltage fixed at 14 0V with a boost mode available which increases output voltage by 0 4V Output is inhibited if no battery is connected but can be overridden for very low voltage batteries 6 0V or manual switching to 24V mode for batteries exhibiting less than 18 0V The TS2X020 can Charge 12V batteries at either 14 0V or 14 4V at a maximum of 40A Charge...

Страница 4: ...tion The Battery Charger should be placed on a level surface with at least 10cm of space at the rear for ventilation 2 4 Controls And Indicators A CHANNEL A AMPS The amount of amps being delivered to the battery for channel A will be displayed on Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 4 of 16 Copyright Material of Intelligent Charging Limited 2015 Printed On 14 06 17 _ _ CHANNEL A CHA...

Страница 5: ...r F CHANNEL B VOLTS The battery voltage for channel A will be displayed on this meter G CHANNEL B STOP BUTTON Press this button to stop channel B charge H CHANNEL B POSITIVE BATTERY LEAD CONNECTOR The battery positive lead is connected here I CHANNEL B 24V INDICATOR This illuminated when a 24V battery is detected J CHANNEL B RUN INDICATOR This is illuminated when the battery is being charged K CHA...

Страница 6: ...ICATOR This illuminated when a 24V battery is detected P CHANNEL A RUN INDICATOR This is illuminated when the battery is being charged Q CHANNEL A NEGATIVE BATTERY LEAD CONNECTOR The battery negative lead is connected here R CHANNEL A START PUSH BUTTON Press this to start the charge operation Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 6 of 16 Copyright Material of Intelligent Charging Lim...

Страница 7: ...ROGRESS AS ARCING CAN OCCUR CAUSING AN EXPLOSION FROM GASSES VENTING FROM BATTERIES BEING PROCESSED THE BATTERY SHOULD ALWAYS BE ISOLATED FROM ANY EQUIPMENT BEFORE BEING CONNECTED Stray ground loops between the attached equipment and the Battery Charger could cause catastrophic damage to the unit and the attached equipment Provided with the unit are two sets of leads terminated with brass battery ...

Страница 8: ... the following sequence must be followed Check that the TS2X020 charger is switched OFF Check that the trip switches fitted to the rear of the equipment are in the ON position Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 8 of 16 Copyright Material of Intelligent Charging Limited 2015 Printed On 14 06 17 _ _ CHANNEL A CHANNEL B Portable Charger TS2X020 START START STOP STOP 24V RUN RUN 24V C...

Страница 9: ...t stated above Once a satisfactory charge has been achieved press the STOP button on the respective channel being used Switch OFF the TS2X020 battery charger Disconnect the Positive lead from the battery first and then from the charger Disconnect the Negative lead from the battery first and then from the charger Connect the battery to it s host equipment in accordance with the procedures laid down...

Страница 10: ...ached their full capacity If the additional 0 4V 0 8V output voltage is required press and hold the START button for two seconds Once a satisfactory charge has been achieved press the STOP button on each channel Switch OFF the TS2X020 battery charger Disconnect the Positive lead from the battery first and then from the charger Disconnect the Negative lead from the battery first and then from the c...

Страница 11: ...llowing procedure Connect battery in accordance with the charging instructions Press and hold the START button While holding the START button momentarily press the STOP button After four seconds the unit should go into RUN mode immediately Release the START button immediately as a further two seconds will go to boost mode Note the RUN lamp will flash to indicate that the START operation was overri...

Страница 12: ...is happens at the beginning of the charge this could be due to failure of one of the supplies and the unit will need repair Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 12 of 16 Copyright Material of Intelligent Charging Limited 2015 Printed On 14 06 17 ...

Страница 13: ...th the unit in the STOPPED mode Measurements must be taken at the power supply output terminals marked MAIN OUTPUT on the sketch above 7 2 Cleaning At yearly intervals it is advisable to ensure that the airflow for the power supplies are not obstructed by dust and dirt To clear any dust and debris the unit must be disconnected from the mains and remove the battery leads from the unit The cover mus...

Страница 14: ...nimum Operating Temperature 0 C Maximum Operating Temperature 50 C Humidity 5 to 95 Non condensing Altitude 0 to 3000 Metres Charge Specifications Max Output Volts Max Output Amps TS2X020 28 0V 28 8V 20 0A TS2X020 14 0V 14 4V 40 0A Doc DWG1021 10 R2 TS2X020 Operators manual odt Page 14 of 16 Copyright Material of Intelligent Charging Limited 2015 Printed On 14 06 17 ...

Страница 15: ...ardous substances and avoid the increasing landfill Product disposal instructions for residential users When you have no further use for it please remove any batteries and dispose of them and the product as per your local authority s recycling processes For more information contact your local authority or the retailer where the product was purchased Product disposal instructions for business users...

Страница 16: ... and fully comply with all procedures shown in the literature and product training familiarisation sessions as misuse or failure to follow the instructions may render this warranty void This warranty is not transferable and excludes routine maintenance consumables parts subject to normal wear and tear service maintenance kits and damage caused by misuse or negligence Warranty claims attributable t...

Отзывы: