IntelliCam MB-900 Скачать руководство пользователя страница 5

 

 
 

SENSOR ID PROGRAMMING:

 

 

To p

ower “on” the sensor simply pull the RED insulator on the battery holder to allow 

current to the sensor.  When powered on, the LED on the top of the sensor will illuminate 
briefly and then begin flashing in 1 second intervals. This is t

he “Range Test Mode”.  Abort 

the Range Test Mode by briefly tapping on the Programming Button. 
 
In the Default Mode, the MB-900 Sensor is programmed for a Sensor ID of 1. You can 
change the ID by performing the following steps. 

 

Be sure the sensor is out of the “Range Test” mode.  (No flashing.) 

  Sensor ID may be set by holding the Programming Button down until the LED 

illuminates. 

 

Immediately after the LED illuminates, release the Programming Button and “tap” 
the number of times for the desired Sensor ID.  The LED will give you a series of 
confirmation flashes that indicate the selected Sensor ID. 

 
 

SENSOR SENSITIVITY PROGRAMMING:

 

 
In the Default Mode, the MB-900 Sensor is programmed for a Sensor ID of 1 and the 
Sensitivity is preset to ‘4’. You can change the ID and Sensitivity by performing the 
following steps. 

  Be sure the sensor is out of the 

“Range Test” mode.  (No flashing.) 

  Set Sensor ID by holding the Programming Button down until the LED illuminates. 

  Immediately after the Red LED illuminates, release the Programming Button and 

“tap” the number of times for the desired Sensor ID.  The LED will give you a series 
of confirmation flashes that indicate the selected Sensor ID. 

  After first setting the Sensor ID, Sensitivity may be set from levels 1 -5, with 5 

being the highest.  Hold the Programming Button down until the Red LED 
illuminates, then 

release the Programming Button and “tap” the number of times to 

set the desired Sensitivity.  The Red LED will give you a series of confirmation 
flashes that indicate the selected Sensor Sensitivity. 

  More or less sensitivity can also be achieved by the positioning of the sensor.

 

Vertical position is less sensitive and horizontal position is more sensitive. 

 

 
NOTE:

 

After approximately 10 minutes, the LED no longer illuminates for covert 

reasons. To reactivate the LED, simply momentarily press the Programming Button. 

 
 
 
 
 
 
 
 
 
 
 
 

Отзывы: