7
Sensor Programming:
When power is applied the IR-903 enters the programming menu, the
BLUE LED
will
illuminate for 5 seconds. The user may press the
PROGRAMMING BUTTON
to program
a Sensor ID and Max Sensitivity. Each button press will reset the menu timeout to 3
seconds. After each programming menu, the IR-903 will play back the entered Sensor ID
and Max Sensitivity. If the user does not program a Sensor ID or Max Sensitivity, the IR-
903 will play back the default Sensor ID of 3, or the default Max Sensitivity of 5.
Sensor ID Menu:
IMPORTANT:
The FBA-1 requires the sensor to be programmed to either ID 1 or ID 2.
The first menu is the Sensor ID menu. When power is first applied the IR-903 enters the
Sensor ID menu, the
BLUE LED
will illuminate for 5 seconds. The user can program a
Sensor ID from 1 to 5 by pressing the
PROGRAMMING BUTTON
1 to 5 times. After the
Sensor ID menu times out, the IR-903 will play back the Sensor ID. If the user does not
program a Sensor ID, the IR-903 will play back the default Sensor ID of 3. The Sensor ID
is transmitted when the IR-903 detects a target. The Sensor ID is used by
some
receivers
to perform different functions.
Max Sensitivity Menu:
The second menu is the Max Sensitivity menu. After the confirmation of the Sensor ID, the
BLUE
LED
will illuminate for 5 seconds, at which time the user can program a Max
Sensitivity from 1 to 5 by pressing the
PROGRAMMING BUTTON
1 to 5 times. After the
Max Sensitivity menu times out, the IR-903 will play back the Max Sensitivity. If the user
does not program a Max Sensitivity, the IR-903 will play back the default Max Sensitivity of
5. The Max Sensitivity determines how far away the IR-903 can detect a target. Setting a
Max Sensitivity less than 5 may be necessary if there is environmental noise in the IR-903
field of view, and the user wished to detect targets
closer
than the environmental noise.
Regardless of the Max Sensitivity, the IR-903 will still use Chameleon
™ Environmental
Adaptive Technology
to lower the sensitivity if the environment becomes unstable. When
the environment is stable again, the IR-903 will raise the sensitivity back up to the Max
Sensitivity.