Troubleshooting 

Symptom 

Probable Causes 

Possible Solutions 

Image not stable 

Defective link or 
equipment  

Verify source and destination equipment and 
cabling 

Unusual colors 

Reversed polarity 

Verify the pinout on both the send and 
receive baluns match. Try swapping pairs.  

Smearing or weak 
video contrast 

Exceeded cable 
distance 

Verify cable grade and total cabling distance 

Horizontal bars 
moving upward in 
background 

Ground loop 
problem 

Verify the source and destination equipment 
are at the same ground potential. Ground the 
source and destination equipment.  

Shaking image 

Ground loop 
problem 

Verify the source and destination equipment 
are at the same ground potential. Ground the 
source and destination equipment. 

Variance in hue  

EMI interference 

Identify possible radiating frequency sources 
and isolate them from the cabling. Use 
shielded twisted pair cabling. 

Background 
pattern 

EMI interference 

Identify possible radiating frequency sources 
and isolate them from the cabling. Use 
shielded twisted pair cabling. 

 

Отзывы: