Intelix AVO-V3AD-F Скачать руководство пользователя страница 2

© Intelix LLC 

 

 

 

 

 

                            www.intelix.com

 

5.

 

If digital audio is to be connected (optional), connect an RCA lead between 
the balun and the digital audio equipment at both ends.  

 
6.

 

Power-on the component video equipment.  Check the image quality and refer 
to troubleshooting if the image quality is unsatisfactory.    

 
Troubleshooting 

Video 

 

 

Symptom 

Probable Causes 

Possible Solutions 

No video 

No continuity in video link 

Verify cable continuity between 
pairs of baluns. 

No video 

Power off 

Check power supplies of video 
equipment. 

No video 

Improper connection or swapped 
pairs 

Check that baluns are connected 
to correct video inputs and 
outputs. 

Unusual colors 

Reversed polarity 

Check wiring and ensure 
straight-through polarity. 

Background pattern 

EMI interference 

Identify possible radiating 
frequency sources (i.e.; wireless 
LANs, switching power 
supplies). Try to isolate them 
from the video connection.  
Use shielded twisted pair 
grounded at both ends. 

Weak contrast 

Exceeded distance 

Verify cable grade. Use higher 
grade cable if necessary. 
Increase contrast on monitor. 

Weak contrast 

Unusual link attenuation 

Verify cable distance using 
ohmmeter or cable tester. 

Image not stable 

Defective link or equipment 

Verify video equipment interface 
integrity. 

Horizontal bars moving 
slowly  

Substantial crosstalk between 
multiple video sources 

Consecutively turn off other 
video sources to determine 
which video source is the cause 
of interference.  

Snowy picture 

Distance is near limit 

Verify cable grade. Use higher 
grade cable if necessary. Reduce 
color intensity at monitor. 

Rolling horizontal bars or 
other interference 

Improper grounding 

Confirm that either the send or 
destination side is grounded.  If 
the source device, cable run, and 
output device are all floating, 
ground the chassis of the source 
or output device. 

Smearing 
 

Exceeded distance 

Verify cable grade. Use higher 
grade cable if necessary. 

 

Digital Audio 

 

 

Symptom 

Probable Causes 

Possible Solutions 

No audio 

Distance exceeded 

Verify cable length between the two 
baluns. 

No audio 

Split pair 

Check if the UTP pairs are split and 
correct.  Each signal pair must be 
twisted. 

No audio 

Power-off. 

Check power supplies of digital audio 
equipment. 

Missing channels 

Cabling problem between 
the decoder/amp and the 
audio speakers. 

Check audio speaker cabling. Verify 
Content is multi-channel and decoder is 
working when attached straight through. 

Noise, static 

EMI interference. 

Check that wiring is not too close to 
transformers and ballasts. 

Noise, static 

Distance exceeded or 
unusual cable attenuation 

Check cable distance and cable grade. 

 
 
 
 
 

 

AVO-V3AD-F System Diagram 