Installation 

 
 
 

 

To install the Intelix AVO-A4-WP110-EU balun, perform the following steps: 
 

1.

 

Turn off power and disconnect the audio equipment by following the manufacturer’s 
instructions.  

2.

 

Make certain that outlets and cross connects to which you will connect the AVO-
A4-WP110-EU are configured properly and labeled correctly to identify the point-
to-point circuit. 

 

 
 
 

 
3.

 

Verify the desired twisted pairs are not being used for 
other LAN or telephony equipment.  

4.

 

Prepare the balun housing by removing the optional 
extension wings. Snap the wing along the break line.  

5.

 

Connect the AVO-A4-WP110-EU to a twisted pair cable, 
such as Cat 5 or Cat 6. Verify the pinout on the balun 
conforms to EIA/TIA 568B standards, as labeled on the 
balun.  

 

 

 
 

 
 
 
 
 
6.

 

Mount the AVO-A4-WP110-EU in a wallbox.  

7.

 

Connect a second compatible Intelix balun to the opposite end of the twisted pair 
cable. Verify the pinout on the balun conforms to EIA/TIA 568B standards. 

8.

 

Connect the RCA outputs from the source equipment to the first  AVO-A4-WP110-
EU.  

9.

 

Connect the RCA inputs from the receive input to the second compatible Intelix 
balun.  

10.

 

Power on the source and destination equipment and test for correct operation.  

Caution:

 Do not attempt to disassemble or alter the balun housing. There are no 

user-serviceable parts inside the unit. Doing so will void your warranty.  

Caution:

 Do not connect the balun to a telecommunication outlet wired to 

unrelated equipment. Doing so may damage the unit or any connected equipment. 
Ensure all connected twisted pair cabling is straight-through (point-to-point). 

Caution:

 When connecting twisted pair cables to the 110 punch-down connector 

on the balun, care should be taken to keep the wires twisted as close to connector 
as possible. This will help eliminate stray EMF interference.  

Caution:

 Do not strip the jacket from the individual wires in the twisted pair 

cable. The 110 punch-down connector will strip the wire jacket during 
termination. Stripping the jacket may result in shorts.   

Содержание AVO-A4-WP110-EU

Страница 1: ... EU transmits analog audio in either direction up to 2 500 feet and is ideal for corporate A V churches schools auditoriums and almost any other situation involving audio distribution The AVO A4 WP110 EU features four female RCA connectors on the front and a 110 punch down termination on the rear The unit includes a 110 termination tool The Intelix AvoCat Series of baluns is the ideal solution for...

Страница 2: ...alun conforms to EIA TIA 568B standards 8 Connect the RCA outputs from the source equipment to the first AVO A4 WP110 EU 9 Connect the RCA inputs from the receive input to the second compatible Intelix balun 10 Power on the source and destination equipment and test for correct operation Caution Do not attempt to disassemble or alter the balun housing There are no user serviceable parts inside the ...

Страница 3: ...ct directly to the 110 punch down connector on the rear of the balun Troubleshooting If your equipment malfunctions with AVO A4 WP110 EU baluns in place follow the troubleshooting procedures below 1 Perform diagnostics on source and destination equipment following the manufacturer s instructions 2 Check all connections and the twisted pair cabling system 3 Verify the 110 punch pattern conforms to ...

Страница 4: ...al Faceplate Color White Dimensions Front 8 59 cm x 8 59 cm x 0 64 cm 3 38 x 3 38 x 0 25 Rear 5 08 cm x 3 81 cm x 3 18 cm 2 00 x 1 50 x 1 25 Shipping Weight 1 0 lbs Ordering Information AVO A4 WP110 EU bulk packaged unit Included Accessories 110 termination tool Warranty 2 years AVO A4 WP110 EU Dual Stereo Audio Balun Intelix Middleton WI 53562 www intelix com Distances and picture quality may be ...

Отзывы: