Low Power Mode

No Signal

No Activity

Changing Low Power Mode Settings

The AS-1H1DP-WP has a low-power or standby mode that it will automatically return to, based upon input signal 

and switching activity.

If the AS-1H1DP-WP detects no video on either the HDMI or the DisplayPort  input for a set amount of time, the 

AS-1H1DP-WP will go into low-power mode.  The default time is 30 minutes, which can be adjusted by using the 

Display Control Software or sending an RS232 command.  The timeout clock is accurate to +/-4%. 

If the unit does not switch inputs (auto or contact closure) or communicate via RS232 for a set amount of time, the 

AS-1H1DP-WP will go into low-power mode. The default time is 3 hours, which can be adjusted by using the Display 

Control Software. The timeout clock is accurate to +/-4%. 

The No Signal and No Activity timeouts can be changed using the Display Control software or by sending the unit 

different timeout commands via RS232.

If sending RS232 commands, the Turn Display Control OFF command (DFG0) command needs to be sent first. 

To disable the timeout, the next two commands to send to the unit would be Disable the “No Signal” Timeout 

(DNS000) and Disable the “No Activity” Timeout (DNA000). These commands are found on 

page 20.

Display Control via RS232

Display Control Software

Display Control Functionality

The  Display  Control  functionality  may  be  set  up  through  RS232  commands  direct  to  the  AS-1H1DP-WP  or  via 

HDBaseT through a compatible receiver. The AS-1H1DP-WP can store commands up to 25 characters (25 hex bytes) 

long.

The Display Control Software is available on the AS-1H1DP-WP product page on libav.com and includes an installation 

and operation guide. The Display Control software interface can transmit commands up to 20 characters (20 hex 

bytes) long.

The AS-1H1DP-WP may be used to control power and input status of the LCD or Projector connected to an HDBaseT 

receiver. When the AS-1H1DP-WP is “woken up from low-power mode, it will send the preprogrammed “Power 

On” command, followed by the “Input Select” command. When the AS-1H1DP-WP times out due to lack of video or 

activity, it will send the preprogrammed “Power Off” command. This will effectively synchronize the power states 

of the display and the AS-1H1DP-WP, eliminating the need for a third party control system in many installations. 

Содержание AS-1H1DP-WP

Страница 1: ...ree 800 530 8998 Fax 719 260 0075 supportlibav libav com HDCP LINK Firmware Reset DisplayPort HDMI Audio HDMI DisplayPortAuto SwitchingWallplate AS 1H1DP WP PoH In HDBT Out 24V IN 12V TX RX GND Auto D...

Страница 2: ......

Страница 3: ...apparatus has been damaged in any way such as the power supply cord or plug is damaged liquid has been spilt or objects have fallen into the apparatus the apparatus has been exposed to rain or moistu...

Страница 4: ...ser to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock 28 WARNING To reduce the risk of electr...

Страница 5: ...11 Auto Switching with Manual Override 11 Device Power 11 12V DC Output Power 12 RS232 Connections 12 Third Party Device Connections 12 General Operation 13 Automatic Switching 13 Contact Closure Swi...

Страница 6: ...Information 18 Factory Reset 19 EDID Configuration 19 Display Control Settings 20 Display Control Queries 21 Display Control Hex Commands 21 Troubleshooting 22 Device does not power on 22 Cannot view...

Страница 7: ...er management system which will put the unit into a low power state after no video for 30 minutes or being inactive for 3 hours by default When using the local power input 12V DC is available for othe...

Страница 8: ...Rear Panels Front Panel HDCP LINK Firmware Reset DisplayPort HDMI Audio 1 2 3 4 1 HDMI input and input status LED 2 Status LEDs and Reset button 3 DisplayPort with analog audio input and input status...

Страница 9: ...ar Panel A Contact closures B 12V DC power input C HDBaseT output with PoH input support D RS232 and 12V DC output HDMI DisplayPortAuto SwitchingWallplate AS 1H1DP WP PoH In HDBT Out 24V IN 12V TX RX...

Страница 10: ...on the AS 1H1DP WP 6 Power on attached audio video devices 7 Apply power to the HDBaseT receiver 8 If the HDBaseT receiver cannot provide power to the AS 1H1DP WP connect the power supply going to the...

Страница 11: ...n place if you wish the unit to switch automatically when a video signal is present The AS 1H1DP WP supports two types of power input PoH Power over HDBaseT and rear panel input When using PoH a compa...

Страница 12: ...capabilities of the AS 1H1DP WP connect the TX ground and RX control signal wires to the removable 4 pole terminal block Consult the manual of the control device s to determine which pins the TX and R...

Страница 13: ...sh button control of the input selection on the AS 1H1DP WP When using Auto switching with manual override the unit will function as described in the Auto section above but pressing one of the overrid...

Страница 14: ...d perfectly for the display In addition to the default EDID pass through mode there are many built in EDID settings to define the source video output resolution The built in EDID tables range from XGA...

Страница 15: ...e sent first To disable the timeout the next two commands to send to the unit would be Disable the No Signal Timeout DNS000 and Disable the No Activity Timeout DNA000 These commands are found on page...

Страница 16: ...if the device RS232 settings have been changed 1 Short the HDMI and DP contact closures to Ground for 10 seconds 2 Without removing the shorted HDMI and DP contact closures short the Auto contact clo...

Страница 17: ...input SET HDMI CR LF SET HDMI CR LF Select DisplayPort input SET DP CR LF SET DP CR LF Get selected input GET IN CR LF GET IN CR LF AND HDMI 1 CR LF OR This response indicates HDMI input is selected D...

Страница 18: ...AUDIO CR LF AUDIO Extern CR LF OR AUDIO Internal CR LF The default baud rate for the AS 1H1DP is 9600 This can be changed to accommodate various installation needs 2400 4800 9600 19200 38400 57600 115...

Страница 19: ...t EDID Configuration Description Command Response UHD 30 EDID UHD CR LF EDID UHD CR LF 1080p EDID FHD CR LF EDID FHD CR LF 720p EDID HD CR LF EDID HD CR LF 1920x1200 EDID WUXGA CR LF EDID WUXGA CR LF...

Страница 20: ...DDC005 DDC CR LF Input Delay Time 10 S CR LF Store the No signal timeout value xxx time in minutes 3 characters DNSxxx Example for 30 min DNS030 DNS CR LF No Signal Time 30 M CR LF Disable the No sig...

Страница 21: ...ription Command Store the ON command for Display Control xx up to 25 bytes 44 4F 4E xx Example 44 4F 4E 54 68 69 73 20 69 73 20 4F 4E Store the OFF command for Display Control xx up to 25 bytes 44 4F...

Страница 22: ...use the included power supply power input on the device Set EDID to pass through Verify output can broadcast surround sound audio Verfiy source content contains surround sound audio Double check RS23...

Страница 23: ...able Requirements Continuous solid core Category 5e or greater with TIA EIA 568B crimp pattern no couplers in line Bandwidth 10 2 Gbps HDBaseT Chipset VS010TX Chassis and Environmental Construction Al...

Страница 24: ...Intelix is a brand of 11675 Ridgeline Drive Colorado Springs Colorado 80921 USA Phone 719 260 0061 Fax 719 260 0075 Toll Free 800 530 8998...

Отзывы: