![Intelbras IVP 2000 SF Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/intelbras/ivp-2000-sf/ivp-2000-sf_user-manual_2073512006.webp)
6
4. Installing the IVP 2000 SF sensor
To install the sensor, carefully read the topic
Care and safety and follow the procedure below:
1. Open the sensor front cover by pressing the sides.
2. With the help of a tool, drill a hole in the back cover for the screws.
3. Insert the 9V battery and position the sensor in the desired location. The IVP 2000 SF does not need to be installed with
an articulator, as it already has a 15° inclination angle.
5. Configuring the IVP 2000 SF sensor (for boards in version
4230312/5 and firmware 2.0.0)
After the sensor is properly installed, make the adjustments according to the information below:
5.1. LED adjustment
The LEDS jumper (JP1) is used to control the LED indication without interfering with the detector. With the switch in posi-
tion L the LEDs are enabled to function normally. With the switch in position D, the LEDs are disabled, that is, they do not
light up. Factory default: L position.
5.2. Sensitivity adjustment of the IVP 2000 SF sensor
The SENS jumper (JP2) is used to control the detection sensitivity. With jumper JP2 in position 1 the sensor provides
maximum sensitivity. With jumper JP2 in position 2 the sensor provides minimum sensitivity. Factory default: position 1.
5.3. IVP 2000 SF sensor operating mode
Once energized, the sensor will operate in the test period for 15 minutes so that the installer can make all sensor positio-
ning adjustments. During this period, at any motion detection, the LED lights up and a trigger is generated. Then the sensor
will operate in eco-mode.
In this mode, the sensor takes a reading of the environment and right after the detection of movement and triggering it
goes into sleep, which can last for a period of 30 seconds (environment with little movement) up to 2 minutes (environ-
ment with a lot of movement). During this period the indication LED is not activated and no new triggers are generated,
as a notification has just been sent to the switch. After the sleep time, the sensor is monitoring the environment until
detecting a new movement.
Trial
period
15 min
Period of
stabilization
Time the sensor remains on
Economy Mode
30 sec - 2 min
After inserting
the battery, the
LED is blinking
and there is no
detection.
At any detection
the LED lights up
and generates a
trigger.
After detecting the first
movement, the sensor turns on
the LED, triggers and enters the
sleep period.
During this period the
LED does not light and
no new triggers are
generated.
After the
hibernation time,
the sensor returns
to detect and
generate triggers
in the central,
starting the cycle
again.
» Advantage of eco-mode: this ability to learn from the environment, means that in places with high degrees of movement,