WARNING:  English  

Important Safety Instructions 

Read all caution and safety statements in this document before performing any of the instructions.  See also Intel Server Boards and Server 
Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards\server\safecert.htm.

ADVERTENCIAS:  Español  

Instrucciones de seguridad importantes 

Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones.  Vea Intel Server 
Boards and Server Chassis Safety Information en el CD Resource y/o en http:\\support.intel.com\support\motherboards\server\safecert.htm.I

SAFETY STEPS:  Whenever you remove the chassis covers to access the inside of the system, follow these steps: 

1. Turn off all peripheral devices connected to the system. 

2. Turn off the system by pressing the power button. 

3. Unplug all AC power cords from the system or from wall outlets. 

4. Label and disconnect all cables connected to I/O connectors or ports on the back of the system. 

5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis 
ground of the system-any unpainted metal surface-when handling components. 

6. Do not operate the system with the chassis covers removed. 

A microprocessor and heat sink may be hot if the system has been running.  Also, there may be sharp pins and edges 
on some board and chassis parts.  Contact should be made with care.  Consider wearing protective gloves. 

NSTRUCCIONES DE SEGURIDAD:  Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las 
siguientes instrucciones: 

1. Apague todos los dispositivos periféricos conectados al sistema. 

2. Apague el sistema presionando el interruptor encendido/apagado. 

3. Desconecte todos los cables de alimentación CA del sistema o de las tomas de corriente alterna. 

4. Identifique y desconecte todos los cables enchufados a los conectores E/S o a los puertos situados en la parte 
posterior del sistema. 

5. Cuando manipule los componentes, es importante protegerse contra la descarga electrostática (ESD).  Puede 
hacerlo si utiliza una muñequera antiestática sujetada a la toma de tierra del chasis - o a cualquier tipo de superficie 
de metal sin pintar. 

6. No ponga en marcha el sistema si se han extraído las tapas del chasis.

Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes.  
También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes.  Por 
ello, se recomienda precaución y el uso de guantes protectores.

Содержание SRCU42E

Страница 1: ...C76895 002 Intel RAID Controller SRCU42E Hardware User s Guide J u n e 2 0 0 4 ...

Страница 2: ... WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not intended for use in medical life saving life sustaining applications Intel may make changes to specifications and product descriptions at any time without notice Intel is a trademark or registered trademark of Intel Corporation...

Страница 3: ...ce when handling components 6 Do not operate the system with the chassis covers removed A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves NSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema si...

Страница 4: ...beschriften und ziehen Sie alle Anschlußkabel von den I O Anschlüssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein Der Mikroprozessor und der Kühler sind möglicherweise erhitzt wenn das System in Bet...

Страница 5: ...03 Canada CE Mark Europe VCCI Mark Japan MIC Mark Korea BSMI DOC Mark Taiwan ACS C Tick Mark Australia PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3 Togliere tutte le spi...

Страница 6: ...y not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Marking Class B USA EMC Marking Class A Canada CANADA ICES 003 CLASS A CANADA NMB 003 CLASSE A EMC Marking Class B Canada CANADA ICES 003 CLASS B CANADA NMB 003 CLASSE B VCCI Marking Class A Japan VCCI Marking Class B Japan BSMI Marking Class A or B...

Страница 7: ...an experienced radio TV technician for help Intel is not responsible for any radio or television interference caused by unauthorized modification of this equipment for substitution or attachment of connecting cables and equipment other than those specified by Intel The correction of interferences casued by such unauhtorized modification substitution or attachement will be the responsibility of the...

Страница 8: ...an RAID Controller SRCU42E into a system Anyone installing an RAID Controller SRCU42E in their RAID system Organization This document has the following chapters and appendixes Chapter 1 Overview provides a general overview of the RAID Controller SRCU42E Chapter 2 Hardware Installation describes the procedures for installing the RAID Controller SRCU42E Chapter 3 Intel RAID Controller SRCU42E Techni...

Страница 9: ...oving a component from the system board or disconnecting a peripheral device from the computer To help prevent electric shock plug the computer and peripheral power cables into properly grounded power sources These cables are equipped with 3 prong plugs to ensure proper grounding Do not use adapter plugs or remove the grounding prong from a cable If you must use an extension cable use a 3 wire cab...

Страница 10: ... mounting bracket Hold a component such as a microprocessor chip by its edges not by its pins Protecting Against Electrostatic Discharge Static electricity can harm delicate components inside your computer To prevent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpaint...

Страница 11: ...20 2 4 After You Have Installed the RAID Controller 25 Chapter 3 Intel RAID Controller SRCU42E Technical Reference 3 1 Overview 26 3 2 Intel RAID Controller SRCU42E Characteristics 28 3 3 Technical Specifications 28 3 3 1 RAID Controller Specifications 28 3 3 2 Array Performance Features 29 3 3 3 Fault Tolerance 30 3 3 4 Electrical Characteristics 30 3 3 5 Thermal and Atmospheric Characteristics 3...

Страница 12: ...2 1 Install the Intel Portable Cache Module 21 2 2 Inserting the Intel RAID Controller SRCU42E in a x8 PCI Express Slot22 2 3 Terminating an Internal SCSI Disk Array 24 3 1 Intel RAID Controller SRCU42E Layout 26 ...

Страница 13: ... s 22 3 1 Intel RAID Controller SRCU42E Headers and Connectors 27 3 2 Intel RAID Controller SRCU42E Characteristics 28 3 3 Intel RAID Controller SRCU42E Specifications 28 3 4 Array Performance Features 29 3 5 Fault Tolerance Features 30 3 6 Maximum Power Requirements 30 ...

Страница 14: ...14 Contents ...

Страница 15: ...RCU42E supports a low voltage differential LVD or a single ended SE SCSI bus With LVD you can use cables up to 12 meters long Throughput on each SCSI channel can be as high as 320 Mbytes s You can install the Intel RAID Controller SRCU42E in PCI Express computer systems with a standard bracket type With this RAID controller in your PCI Express system you can connect SCSI devices over a SCSI bus Fo...

Страница 16: ...te DIMM can be installed Support for a x8 PCI Express interface The RAID Controller SRCU42E has two internal and two external SCSI connectors Support for RAID levels 0 striping 1 mirroring 5 striping and parity data across all drives 10 mirroring and striping and 50 RAID 5 and striping Advanced array configuration and management utilities Battery backup for up to 72 hours with the 128 Mbyte Intel ...

Страница 17: ...CSI Channel Up to 15 Wide SCSI devices SCSI Channels 2 SCSI Data Transfer Rate Up to 320 Mbytes s per channel SCSI Bus LVD or SE Cache Function Write back requires Portable Cache Module Write through Adaptive Read Ahead Non Read Ahead Read Ahead Cache I O Direct I O Multiple Logical Drives Arrays per Controller Up to 40 logical drives per controller Online Capacity Expansion Yes Dedicated and Pool...

Страница 18: ...target ID Note Configuration on Disk does not work if you change both the RAID Controller SRCU42E and the SCSI connectors to different connectors on the new RAID controller It works only if you make one change at a time 1 3 3 Drive Roaming The RAID Controller SRCU42E supports drive roaming across channels on the same RAID Controller SRCU42E Drive roaming lets an Intel Raid RAID Controller SRCU42E ...

Страница 19: ...AID controller An Intel RAID Controller SRCU42E A host computer with an available x8 PCI Express expansion slot The Resource CD The necessary internal and or external SCSI cables Ensure that the SCSI cables conform to all SCSI specifications Ultra Ultra2 Ultra160 or Ultra320 SCSI hard disk drives although backward compatible SCSI uses the speed of the slowest device on the bus The Intel Portable C...

Страница 20: ...tailed Installation This section provides detailed instructions for installing the Intel RAID Controller SRCU42E 1 Unpack Unpack and remove the RAID Controller SRCU42E Inspect it for damage If it appears damaged or if any items listed below are missing contact your Intel support representative The Intel RAID Controller SRCU42E is shipped with The Resource CD which contains Intel RAID drivers for s...

Страница 21: ...ystem documentation for instructions 4 Check the Jumpers Ensure that the jumper settings on the your RAID Controller SRCU42E are correct See Chapter 3 Intel RAID Controller SRCU42E Technical Reference for diagrams of the RAID Controller SRCU42Es with their jumpers and connectors 5 Install the Intel RAID Controller SRCU42E Select a x8 PCI Express slot and align the RAID Controller SRCU42E PCI bus c...

Страница 22: ...que TIDs for non disk devices CD ROM or tapes regardless of the channel where they are connected The Intel RAID Controller SRCU42E automatically occupies TID 7 which is the highest priority The arbitration priority for a SCSI device depends on its TID Table 2 1 Target ID s Priority Highest Lowest TID 7 6 5 2 1 0 15 14 9 8 32 bit slot 64 bit slots 3 3 V 5 V Edge of server board Bracket Screw x8 PCI...

Страница 23: ...n 8 drive Ultra SCSI system and no longer than 3 meters for a 6 drive Ultra SCSI system Use active termination Avoid clustering the cable nodes The cable stub length must be no greater than 0 1 meter 4 inches Use high impedance cables Route SCSI cables carefully 8 Set SCSI Termination The SCSI bus is an electrical transmission line and must be terminated properly to minimize reflections and losses...

Страница 24: ...ssage appears The firmware takes several seconds to initialize During this time the RAID Controller SRCU42E scans the SCSI channel s The BIOS Configuration utility prompt times out after several seconds The second portion of the BIOS message displays the Intel RAID Controller SRCU42E number firmware version and cache SDRAM size The numbering of the controllers follows the PCI slot scanning order u...

Страница 25: ...nstalled the RAID Controller After installation you must configure the RAID Controller SRCU42E and install the operating system driver The Intel RAID Software User s Guide instructs you about the configuration options and how to set them on your RAID Controller SRCU42E ...

Страница 26: ... used in systems that have a x8 PCI Express slot with a PCI standard bracket type PCI Express goes beyond the PCI specification in that it is intended as a unifying I O architecture for a variety of systems including desktops workstations mobile server communications and embedded devices Figure 3 1 Intel RAID Controller SRCU42E Layout J12 Channel 0 External Ultra High 68 pin SCSI Connector Density...

Страница 27: ...tion No jumper installed enables onboard SCSI termination See J17 and J18 This is the default J6 SCSI Termination Enable Channel 1 3 pin connector J7 Serial Port RS232 3 pin header Connector is for diagnostic purposes Pin 1 RXD Receive Data Pin 2 TXD Transmit Data Pin 3 GND Ground J9 Internal SCSI Channel 0 connector 68 pin header Internal high density SCSI bus connector Connection is optional J10...

Страница 28: ... LVD SE Signaling Ultra320 SCSI Data Transfers SCSI Features SCSI Termination Yes Yes 16 bit SE or LVD interfaces Up to 320 Mbytes s as well as Fast Ultra Ultra2 and Ultra160 speeds Synchronous offsets up to 62 Plug n Play Scatter Gather Activity LED Active Single Ended or LVD Table 3 3 Intel RAID Controller SRCU42E Specifications Specification Description Processor PCI Controller Intel 80332 I O ...

Страница 29: ...l RAID Controller SRCU42E Specifications Cont Specification Description Table 3 4 Array Performance Features Specification Intel RAID Controller SRCU42E x8 PCI Express Host Data Transfer Rate 2 Gbytes second full duplex 4 Gbyte second total theoretical Drive Data Transfer Rate 320 Mbytes second per SCSI channel Maximum Scatter Gathers 26 elements Maximum Size of I O Requests 6 4 Mbytes in 64 Kbyte...

Страница 30: ...ge and transit environment for the Intel RAID Controller SRCU42E Temperature range 40 C to 105 C dry bulb Relative humidity range 5 to 90 noncondensing Table 3 5 Fault Tolerance Features Specification Intel Raid Controller SRCU42E Support for SMART 1 1 The Self Monitoring Analysis and Reporting Technology SMART detects up to 70 percent of all predictable disk drive failures SMART also monitors the...

Страница 31: ...roller SRCU42E meets or exceeds the requirements of UL flammability rating 94 V0 Each bare board is also marked with the supplier s name or trademark type and UL flammability rating Since these boards are installed in a PCI bus slot all voltages are below the SELV 42 4 V limit ...

Страница 32: ... to a common ground Domain Validation Domain Validation is a software procedure in which a host queries a device to determine its ability to communicate at the negotiated Ultra320 data rate EEPROM Electronically Erasable Programmable Read Only Memory External SCSI Device A SCSI device installed outside the computer cabinet These devices are connected together using specific types of shielded cable...

Страница 33: ...CSI device on the SCSI bus Each SCSI bus has eight available SCSI IDs numbered 0 through 7 or 0 through 15 for Wide SCSI The RAID controller host controller usually gets the highest ID 7 or 15 giving it priority to control the bus Single Ended SCSI A hardware specification for connecting SCSI devices It references each SCSI signal to a common ground This is the most common method as opposed to dif...

Отзывы: