Intel
®
SRCU41L Raid Controller User Manual
11
Hardware Installation
If you want to run the Intel
®
Raid Controller SRCU41L Configuration utility or BIOS Console at
this point, press the appropriate keys when this message appears:
Press <CTRL><G> for WebBIOS
2.3.1
Resolving a Configuration Mismatch
If the replacement controller has a previous configuration, a message displays during the power-on
self test (POST) stating that there is a configuration mismatch. A configuration mismatch occurs
when the configuration data in the NVRAM and the hard disk drives are different. You need to
update the configuration data in the NVRAM with the data from the hard disk drive.
Perform the following steps to resolve the mismatch.
1. Press <Ctrl> <G> when prompted during bootup to access the BIOS Configuration Utility.
2. Select
Configure—> View/Add Configuration
.
This gives you the option to view both the configuration on the NVRAM and the hard drive
disk.
3. Select the configuration on disk.
4. Press <ESC> and select
YES
to update NVRAM.
5. Exit and reboot.
2.4
After You Have Installed the Storage Adapter
After Intel
®
Raid Controller SRCU41L installation, you must configure the Intel
®
Raid Controller
SRCU41L and install the operating system driver. The
Software User’s Guide
instructs you on the
configuration options and how to set them on your Intel
®
Raid Controller SRCU41L. The
Software
User’s Guide
also provides detailed installation instructions for operating system drivers.