background image

18

Intel® RAID Controller SRCSASLS4I Hardware User’s Guide

Additional safety guidelines:

When you disconnect a cable, pull on its connector or on its strain-relief loop, not on 
the cable itself. Some cables have a connector with locking tabs; if you are 
disconnecting this type of cable, press in on the locking tabs before disconnect the 
cable. As you pull connectors apart, keep them evenly aligned to avoid bending any 
connector pins. Also, before you connect a cable, make sure both connectors are 
correctly oriented and aligned.

Handle components and cards with care. Don't touch the components or contacts on 
a card. Hold a card by its edges or by its metal mounting bracket. Hold a component 
such as a microprocessor chip by its edges, not by its pins.

Protecting against electrostatic discharge

Static electricity can harm delicate components inside your computer. To prevent 
static damage, discharge static electricity from your body before you touch any of 
your computer's electronic components, such as the microprocessor. You can do so 
by touching an unpainted metal surface, such as the metal around the card-slot 
openings at the back of the computer.

As you continue to work inside the computer, periodically touch an unpainted metal 
surface to remove any static charge your body may have accumulated. In addition to 
the preceding precautions, you can also take the following steps to prevent damage 
from electrostatic discharge (ESD):

When unpacking a static-sensitive component from its shipping carton, do not 
remove the component from the antistatic packing material until you are ready to 
install the component in your computer. Just before unwrapping the antistatic 
packaging, be sure to discharge static electricity from your body.

When transporting a sensitive component, first place it in an antistatic container or 
packaging.

Handle all sensitive components in a static-safe area. If possible, use antistatic floor 
pads and workbench pads.

Содержание SRCSASLS4I - RAID Controller

Страница 1: ...Intel RAID Controller SRCSASLS4I Hardware User s Guide Intel Order Number E33167 002...

Страница 2: ...S INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not int...

Страница 3: ...nefit from this book are Engineers who are designing an Intel RAID Controller SRCSASLS4I storage adapter into a system Anyone installing an Intel RAID Controller SRCSASLS4I storage adapter in their RA...

Страница 4: ...iv Intel RAID Controller SRCSASLS4I Hardware User s Guide...

Страница 5: ...lation 7 Requirements 7 Install the RAID Controller 7 Configure the RAID Controller 10 Replacing a Controller Resolving a Config Mismatch 10 Chapter 3 Intel RAID Controller SRCSASLS4I Characteristics...

Страница 6: ...vi Intel RAID Controller SRCSASLS4I Hardware User s Guide...

Страница 7: ...for the RAID controller even during system failures Benefits of SAS SAS is a serial point to point enterprise level device interface that leverages the proven SCSI protocol set SAS is a convergence o...

Страница 8: ...her SATA II devices Serial Management Protocol SMP Topology management information sharing with expanders Serial Tunneling Protocol STP support for SATAII through expander interfaces Operating System...

Страница 9: ...ES2 Enclosure management support Fault indicators per drive Drive coercion auto resizing to match existing disks Auto detection of failed drives with transparent rebuild There must be disk activity I...

Страница 10: ...ta is not in the cache Direct I O Reads data directly from disk not cache Redundancy through Configuration stored in nonvolatile RAM and on the drives COD Hot swap support Optional battery backup for...

Страница 11: ...5 to RAID 0 RAID 6 to RAID 0 With OCE migrations supported are RAID 0 to RAID 1 RAID 0 to RAID 5 RAID 1 to RAID 5 Beep Codes Short beep 1 second on 1 second off Array is degraded but no data lost Lon...

Страница 12: ...6 Intel RAID Controller SRCSASLS4I Hardware User s Guide...

Страница 13: ...tion SAS or SATA 3 0 hard drives Note Intel Corporation strongly recommends using an uninterruptible power supply UPS Install the RAID Controller 1 Turn off the power to the system and all drives encl...

Страница 14: ...ler SRCSASLS4I 5 For the four drives ports 0 3 connect one 4 port combined end of an internal cable to the connector See the following figure To prevent throughput problems use the cable provided or u...

Страница 15: ...LS4I Hardware User s Guide 9 Figure 3 Connecting Cable between the RAID Controller and Drives Backplane 6 Install the server system cover and connect the power cords See your server system documentati...

Страница 16: ...e server board 3 See the Quick Start User s Guide and the Software User s Guide for instructions to configure the RAID controller and to install the operating system drivers Replacing a Controller Res...

Страница 17: ...n to disk J3 Drive Activity LED Header 2 pin connector LED signal for drive activity J4 Debug Connector 2 pin connector Reserved J5 Universal Asynchronous Receiver Transmitter UART 4 pin connector For...

Страница 18: ...2 5 Gbps SATA bus speed 3 Gbps per port point to point Serial port 3 pin RS232 compatible connector for debug use only SAS controller LSI 1078 SAS SATA ports 1x4 internal port up to 4 direct attached...

Страница 19: ...ion OCE and Patrol Read Cache options Write back or Write through Read Ahead Adaptive Read Ahead NonRead Ahead Cache I O or Direct I O Self Monitoring Analysis and Reporting Technology SMART support D...

Страница 20: ...oard is marked with the supplier name or trademark type and UL flammability rating For the boards installed in a PCI bus slot all voltages are lower than the SELV 42 4 V limit PCI 12 V PCI 3 3 Aux PCI...

Страница 21: ...use drive roaming 1 Turn off the power to the system and all drives enclosures and system components Remove the power cord s 2 Follow the instructions that came with your server system to remove the s...

Страница 22: ...tem and all drives enclosures and system components Remove the power cord s 3 Follow the instructions that came with your server system to remove the server cover 4 Disconnect the cables from the driv...

Страница 23: ...protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your com...

Страница 24: ...nt static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal surfa...

Страница 25: ...onnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground o...

Страница 26: ...alter f r Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Si...

Страница 27: ...dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie...

Страница 28: ...reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vo...

Страница 29: ...erruptor activado desactivado en el panel frontal no desconecta la corriente alterna del sistema Para desconectarla deber desenchufar todos los cables de corriente alterna de la pared o desconectar la...

Страница 30: ...mpruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extra dos anteriormente tens ndolos firmemente...

Страница 31: ...del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sistema...

Страница 32: ...26 Intel RAID Controller SRCSASLS4I Hardware User s Guide...

Страница 33: ...iance Class B FCC ICES 003 USA Canada CISPR 22 International EN55022 Europe EN55024 Europe CE EMC Directive 89 336 EEC Europe VCCI Japan AS NZS 3548 Australia New Zealand BSMI CNS13438 Taiwan RRL MIC...

Страница 34: ...the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including int...

Страница 35: ...ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Страница 36: ...tal apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites bruits...

Отзывы: